Suppr超能文献

[校正后] 滑行路径直径的增加提高了F6 Skytaper的定心能力。

Increase in [corrected] the glyde path diameter improves the centering ability of F6 Skytaper.

作者信息

Troiano Giuseppe, Dioguardi Mario, Cocco Armando, Zhurakivska Khrystyna, Ciavarella Domenico, Muzio Lorenzo Lo

机构信息

Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy.

出版信息

Eur J Dent. 2018 Jan-Mar;12(1):89-93. doi: 10.4103/ejd.ejd_231_17.

Abstract

OBJECTIVE

The aim of this study was to assess the impact of glide path preparation, performed with PathGlider 0.15 (Komet Brasseler GmbH & Co., Lemgo, Germany) and PathGlider 0.20 (Komet Brasseler GmbH & Co., Lemgo, Germany), on the centering ability of 25-size F6 Skytaper in J-shape simulated root canals, compared with no glide path executed.

MATERIALS AND METHODS

Sixty J-shaped ISO 15 0.02 taper endo training blocks (Dentsply Maillefer) were assigned to three groups ( = 20 for each group). Photographic images were taken on endoblocks before and after shaping procedures. After superimposition, the software AutoCAD 2013 (Autodesk Inc., San Rafael, USA) was used for record the centering and shaping ability at 9 different levels from the apex.

RESULTS

Shaping procedures including the using of PathGlider 0.20 resulted in a lower amount of resin removed and in a clear improvement of centering ability of the Skytaper 0.25 at almost all reference point levels.

CONCLUSIONS

Within the limitations of this study, it could be concluded that the glide path procedure, performed with the PathGlider 0.20 before the shaping with 25-size F6 Skytaper, might determine a lower amount of resin removed and a better centering ability compared with the groups without glide path procedure and those treated with PathGlider 0.15.

摘要

目的

本研究旨在评估使用PathGlider 0.15(德国莱姆戈的Komet Brasseler GmbH & Co.公司)和PathGlider 0.20(德国莱姆戈的Komet Brasseler GmbH & Co.公司)进行引导通路预备,与不进行引导通路预备相比,对25号F6 SkyTaper锉在J形模拟根管中的定心能力的影响。

材料与方法

将60个J形ISO 15 0.02锥度的根管治疗训练模块(登士柏迈丽菲公司)分为三组(每组n = 20)。在预备程序前后对根管治疗模块拍摄照片。叠加后,使用软件AutoCAD 2013(美国圣拉斐尔的欧特克公司)记录从根尖起9个不同水平处的定心和预备能力。

结果

包括使用PathGlider 0.20的预备程序导致去除的树脂量更少,并且在几乎所有参考点水平处SkyTaper 0.25的定心能力都有明显改善。

结论

在本研究的局限性范围内,可以得出结论,与未进行引导通路预备的组以及使用PathGlider 0.15治疗的组相比,在使用25号F6 SkyTaper进行预备之前使用PathGlider 0.20进行引导通路预备可能会减少树脂去除量并提高定心能力。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1412/5883482/de359709a59a/EJD-12-89-g002.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验