Dioguardi Mario, Sovereto Diego, Aiuto Riccardo, Laino Luigi, Illuzzi Gaetano, Laneve Enrica, Raddato Bruna, Caponio Vito Carlo Alberto, Dioguardi Antonio, Zhurakivska Khrystyna, Troiano Giuseppe, Lo Muzio Lorenzo
Department of Clinical and Experimental Medicine, University of Foggia, Via Rovelli 50, 71122 Foggia, Italy.
Department of Biomedical, Surgical, and Dental Science, University of Milan, 20122 Milan, Italy.
Materials (Basel). 2019 Jul 8;12(13):2190. doi: 10.3390/ma12132190.
Sterilization is a fundamental step in the reuse of endodontic instruments. The sterilization procedure involves disinfection, cleaning, washing, drying, packaging, and sterilization by heat. Heat sterilization can lead to changes in the physical and mechanical properties of dental instruments. These changes can affect the external surfaces via micropitting, corrosion, a reduction in cutting capacity, and/or an influence on the resistance to cyclic fatigue or to torsional fatigue. In this study, we examined the modification of the torsional properties of endodontic instruments after hot sterilization, and compared the properties with instruments not subjected to hot sterilization cycles in terms of resistance to torsional fatigue and deflection angle in NiTi and steel instruments. The following work was performed based on the PRISMA indications. Studies were identified through bibliographic research using electronic databases. A total of 725 records were identified in the PubMed and Scopus databases. A total of 685 records remained after exclusion by year of publication (1979 to 2019). With the application of the eligibility criteria (all articles pertaining to the issue of sterilization in endodontics), we found 146 articles, which decreased to 130 articles after elimination of duplications. There were 45 articles that studied the influences of sterilization procedures on the physical and mechanical characteristics of the instruments, and 12 that measured parameters related to resistance to torsional fatigue. Applying the inclusion and exclusion criteria resulted in a total of eight articles for quantitative analysis. The meta-analysis results show a pejorative effect of torsional fatigue for NiTi instruments subjected to heat sterilization compared to the non-sterilized control.
灭菌是牙髓治疗器械再利用的一个基本步骤。灭菌程序包括消毒、清洁、冲洗、干燥、包装以及热灭菌。热灭菌会导致牙科器械的物理和机械性能发生变化。这些变化可通过微点蚀、腐蚀、切割能力降低和/或对循环疲劳或扭转疲劳抗性的影响来作用于器械外表面。在本研究中,我们检查了热灭菌后牙髓治疗器械扭转性能的改变,并在镍钛合金和钢制器械的扭转疲劳抗性和偏转角方面,将这些性能与未经过热灭菌循环的器械进行了比较。以下工作是根据PRISMA指南进行的。通过使用电子数据库进行文献检索来识别研究。在PubMed和Scopus数据库中总共识别出725条记录。按出版年份(1979年至2019年)排除后,还剩下685条记录。应用纳入标准(所有与牙髓病学中灭菌问题相关的文章),我们找到了146篇文章,在消除重复项后减少到130篇。有45篇文章研究了灭菌程序对器械物理和机械特性的影响,12篇文章测量了与扭转疲劳抗性相关的参数。应用纳入和排除标准后,共有8篇文章用于定量分析。荟萃分析结果表明,与未灭菌的对照组相比,经过热灭菌的镍钛合金器械的扭转疲劳有不良影响。