Faculty of Life Sciences and Medicine, Academic Department of Physiotherapy, Guy's Campus, King's College London, London, SE1 1UL, UK.
One Small Step Gait Laboratory, Guy's Hospital, Guy's & St Thomas' Foundation NHS Trust, London, SE1 7EH, UK.
Aging Clin Exp Res. 2019 Feb;31(2):257-263. doi: 10.1007/s40520-018-0945-6. Epub 2018 Apr 17.
Impairments in dynamic balance have a detrimental effect in older adults at risk of falls (OARF). Gait initiation (GI) is a challenging transitional movement. Centre of pressure (COP) excursions using force plates have been used to measure GI performance. The Nintendo Wii Balance Board (WBB) offers an alternative to a standard force plate for the measurement of CoP excursion.
To determine the reliability of COP excursions using the WBB, and its feasibility within a 4-week strength and balance intervention (SBI) treating OARF.
Ten OARF subjects attending SBI and ten young healthy adults, each performed three GI trials after 10 s of quiet stance from a standardised foot position (shoulder width) before walking forward 3 m to pick up an object. Averaged COP mediolateral (ML) and anteroposterior (AP) excursions (distance) and path-length time (GI-onset to first toe-off) were analysed.
WBB ML (0.866) and AP COP excursion (0.895) reliability (ICC) was excellent, and COP path-length reliability was fair (0.517). Compared to OARF, healthy subjects presented with larger COP excursion in both directions and shorter COP path length. OARF subjects meaningfully improved their timed-up-and-go and ML COP excursion between weeks 1-4, while AP COP excursions, path length, and confidence-in-balance remained stable.
COP path length and excursion directions probably measure different GI postural control attributes. Limitations in WBB accuracy and precision in transition tasks needs to be established before it can be used clinically to measure postural aspects of GI viably.
The WBB could provide valuable clinical evaluation of balance function in OARF.
动态平衡障碍会对有跌倒风险的老年人(OARF)造成不利影响。步态启动(GI)是一项具有挑战性的过渡运动。使用压力板测量中心压力(COP)偏移量已用于测量 GI 性能。任天堂 Wii 平衡板(WBB)为 COP 偏移量的测量提供了一种替代标准力板的方法。
确定 WBB 测量 COP 偏移量的可靠性,以及在针对 OARF 的为期 4 周的力量和平衡干预(SBI)中使用的可行性。
10 名参加 SBI 的 OARF 受试者和 10 名年轻健康成年人,在从标准脚位(肩宽)进行 10 秒安静站立后,分别进行 3 次 GI 试验,然后向前走 3 米捡起一个物体。分析平均 COP 横向(ML)和前后(AP)偏移量(距离)和路径长度时间(GI 起始到第一脚趾离地)。
WBB ML(0.866)和 AP COP 偏移量(0.895)可靠性(ICC)非常好,COP 路径长度可靠性为中等(0.517)。与 OARF 相比,健康受试者在两个方向上的 COP 偏移量都更大,COP 路径长度更短。OARF 受试者在第 1-4 周之间明显提高了他们的计时起身和 ML COP 偏移量,而 AP COP 偏移量、路径长度和平衡信心保持稳定。
COP 路径长度和偏移方向可能测量不同的 GI 姿势控制属性。在将 WBB 用于临床测量 GI 姿势方面之前,需要确定其在过渡任务中的准确性和精度限制。
WBB 可以为 OARF 的平衡功能提供有价值的临床评估。