Long-term Wear Data From a Prospective Multicenter Study of Second-Generation Highly Cross-linked Polyethylene Inserts in Total Hip Arthroplasty.

作者信息

Bonutti Peter M, Mesko J Wesley, Ramakrishnan Rama

出版信息

Orthopedics. 2018 Jul 1;41(4):e529-e533. doi: 10.3928/01477447-20180511-03. Epub 2018 May 18.

Abstract

In a prospective multicenter trial on highly cross-linked polyethylene inserts in patients undergoing total hip arthroplasty, 118 patients consented to 10-year follow-up. Medium-term follow-up results showed low wear at 5 and 7 years after surgery. The current study focuses on long-term data at 10 years. Patients were followed up by either phone or office visit to collect long-term clinical data including Harris hip score and adverse events. There were 2 deaths and 2 revisions, 1 at 6.5 years for pelvic cyst and severe pain and another at 8.0 years for recurrent dislocation. For wear analysis, suitable radiographic images for 48 patients (52 hips) at minimum 10-year follow-up were available. Mean age of the cohort was 62.5 years (62% female). Femoral head penetration was measured using Martell's method from the radiographic images between the 6-week and the subsequent follow-ups. Polyethylene wear rate was calculated from the penetration data. Descriptive statistics were performed. There was no evidence of significant oxidation or locking mechanism failure. Mean Harris hip score of the group was 94.3. No osteolysis was noted by an independent radiographic reviewer. The slope of the bestfit regression line to the femoral head penetration data, which represents the overall linear wear rate of the polyethylene, was 0.014 mm/y. The wear rate was significantly below the 0.100 mm/y critical threshold for development of osteolysis. Volumetric wear rate was calculated to be 11.6 mm/y. The second-generation highly cross-linked polyethylene acetabular inserts had low wear in the long term (10.3 years) with no incidence of osteolysis. [Orthopedics. 2018; 41(4):e529-e533.].

摘要

在一项针对接受全髋关节置换术患者使用高度交联聚乙烯内衬的前瞻性多中心试验中,118名患者同意进行10年随访。中期随访结果显示术后5年和7年磨损率较低。当前研究聚焦于10年的长期数据。通过电话或门诊随访患者,以收集包括Harris髋关节评分和不良事件在内的长期临床数据。有2例死亡和2例翻修手术,1例在6.5年时因盆腔囊肿和严重疼痛进行翻修,另1例在8.0年时因复发性脱位进行翻修。对于磨损分析,可获得48例患者(52髋)至少10年随访的合适X线影像。该队列的平均年龄为62.5岁(62%为女性)。使用Martell方法从6周及后续随访的X线影像中测量股骨头的穿透情况。根据穿透数据计算聚乙烯磨损率。进行描述性统计。没有显著氧化或锁定机制故障的证据。该组的平均Harris髋关节评分为94.3。独立的X线影像评估者未发现骨溶解。代表聚乙烯总体线性磨损率的股骨头穿透数据的最佳拟合回归线斜率为0.014 mm/年。磨损率显著低于骨溶解发生的临界阈值0.100 mm/年。体积磨损率计算为11.6 mm/年。第二代高度交联聚乙烯髋臼内衬长期(10.3年)磨损率低,且无骨溶解发生。[《骨科学》。2018;41(4):e529 - e533。]

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验