Suppr超能文献

50 岁及以下患者钴铬合金股骨头在超交联聚乙烯上的全髋关节置换术 15 年结果。

Fifteen-Year Results of Total Hip Arthroplasty With Cobalt-Chromium Femoral Heads on Highly Cross-Linked Polyethylene in Patients 50 Years and Less.

机构信息

Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, MO.

Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, AR.

出版信息

J Arthroplasty. 2019 Jun;34(6):1143-1149. doi: 10.1016/j.arth.2019.01.071. Epub 2019 Feb 5.

Abstract

BACKGROUND

Highly cross-linked polyethylene (HXLPE) is the most commonly used bearing surface in total hip arthroplasty (THA) because of its superior wear properties, but long-term results in young patients are limited. Mid-term survivorship has been promising; however, polyethylene wear rates and need for revision surgeries remain a concern in this population. The purpose of our study is to investigate polyethylene wear rates, implant survivorship, wear-related revisions, and patient-reported outcomes in a young patient cohort at 15-year follow-up.

METHODS

We performed a retrospective study of a prospective longitudinal cohort of 82 consecutive patients (89 hips) who underwent primary THA with an HXLPE acetabular liner and a cobalt-chromium femoral head. The mean age at the time of surgery for the cohort was 38.8 years (range 12-50). All patients received HXLPE liners with a cementless acetabular component coupled with a cobalt-chrome femoral head through a posterior approach with a cementless femoral component. All components were from a single manufacturer. We recorded University of California, Los Angeles Activity, and modified Harris Hip Scores. Wear calculations were made using the Martell Hip Analysis Suite (Version 8.0.4.3).

RESULTS

At average 15 years (range 13.1-18.5), there was a revision-free survivorship of 97.8% in our HXLPE group with no wear-related revisions. We observed a linear wear rate of 0.0185 mm/y (standard deviation 0.05) after accounting for a 1-year bedding-in period. The volumetric wear rate was found to be 12.80 mm/y (standard deviation 22.69). These numbers are registered as clinically undetectable and are comparable to steady state wear rates in the same cohort of patients at earlier time points. We found no radiographic changes concerning osteolysis. We observed excellent patient-reported outcomes at this time point with improvements in modified Harris Hip Scores (35.3 [22.5], P < .0001) and University of California, Los Angeles Activity Scores (median 6.0, P < .0001).

CONCLUSION

At 15-year follow-up, we demonstrated that HXLPE bearings in this young cohort had excellent wear properties, maintained superior clinical improvements, and underwent no wear-related revision operations. The HXLPE and cobalt-chrome bearing couple continues to be extremely effective 15 years after primary THA in patients less than 50 years.

LEVEL OF EVIDENCE

IV.

摘要

背景

超高分子量聚乙烯(HXLPE)因其优异的耐磨性能,是全髋关节置换术(THA)中最常用的关节面材料,但在年轻患者中的长期效果有限。中期随访结果令人鼓舞;然而,在这一年龄段,聚乙烯磨损率和翻修手术的需求仍然是一个关注点。我们的研究目的是在 15 年随访时,调查年轻患者队列中 HXLPE 关节面的聚乙烯磨损率、假体生存率、与磨损相关的翻修手术以及患者报告的结果。

方法

我们对 82 例连续患者(89 髋)进行了前瞻性纵向队列研究,这些患者均接受了 HXLPE 髋臼衬垫和钴铬股骨头的初次 THA。该队列患者的平均手术年龄为 38.8 岁(12-50 岁)。所有患者均通过后路接受了无水泥髋臼组件和钴铬股骨头的 HXLPE 衬垫,同时接受了无水泥股骨组件。所有组件均来自单一制造商。我们记录了加利福尼亚大学洛杉矶活动评分(UCLA)和改良 Harris 髋关节评分。使用 Martell Hip Analysis Suite(版本 8.0.4.3)计算磨损量。

结果

平均随访 15 年(范围 13.1-18.5 年),我们的 HXLPE 组无磨损相关翻修,翻修生存率为 97.8%。在考虑 1 年的磨合期后,我们观察到线性磨损率为 0.0185mm/y(标准差 0.05)。体积磨损率为 12.80mm/y(标准差 22.69)。这些数值被认为是临床不可检测的,与同一患者队列在更早时间点的稳定状态磨损率相当。我们未发现与骨溶解相关的影像学变化。此时,我们观察到患者报告的结果非常出色,改良 Harris 髋关节评分(35.3[22.5],P<0.0001)和加利福尼亚大学洛杉矶活动评分(中位数 6.0,P<0.0001)均得到改善。

结论

在 15 年随访时,我们发现该年轻患者队列中的 HXLPE 关节面具有优异的耐磨性能,保持了优异的临床改善效果,并且没有发生与磨损相关的翻修手术。在年龄小于 50 岁的初次 THA 后 15 年,HXLPE 和钴铬关节面仍非常有效。

证据等级

IV 级。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验