Suppr超能文献

巩膜镜泪液清除对角膜水肿及镜片后泪液动力学的影响:一项初步研究。

Effects of Scleral-lens Tear Clearance on Corneal Edema and Post-lens Tear Dynamics: A Pilot Study.

作者信息

Tan Bo, Zhou Yixiu, Yuen Tiffany L, Lin Kristina, Michaud Langis, Lin Meng C

机构信息

Clinical Research Center, School of Optometry, University of California, Berkeley, Berkeley, California.

School of Optometry, Université de Montréal, Montreal, Quebec, Canada.

出版信息

Optom Vis Sci. 2018 Jun;95(6):481-490. doi: 10.1097/OPX.0000000000001220.

Abstract

SIGNIFICANCE

The present study with small-diameter scleral lenses (SLs) revealed that post-lens tear thickness (PoLTT) was significantly associated with post-lens tear mixing, but not with central corneal edema, after short-term SL wear.

PURPOSE

The aim of this study was to investigate the influence of SL tear clearance (PoLTT) on central corneal thickness and post-lens tear dynamics during 5-hour lens wear.

METHODS

Neophytes with no active ocular disease were fitted bilaterally with SLs (hofocon A; 15.6-mm diameter; ~438-μm thickness; 97 Dk; 1.44 refractive index) with various initial PoLTT values ranging from 74 to 543 μm. Central corneal thickness and PoLTT were measured using optical coherence tomography during lens wear. Tear mixing was assessed using fluorogram and "out-in" method.

RESULTS

The mean central corneal edema after 5-hour lens wear was 1.51% (95% confidence interval, 1.26 to 1.76%; P < .001), reached its peak at 2-hour post-lens insertion (1.65% [95% confidence interval, 1.45 to 1.85%]), and was independent of PoLTT. The fastest fluorescence decay of the post-lens tear film was observed superiorly. The fluorescence decay rate increased from center to periphery in all quadrants except superiorly. An inverse relationship was found between PoLTT and fluorescence decay rate at both 20-minute and 5-hour wear after lens insertion (P < .05). Excluding observations with out-in time exceeding 5 minutes, we found a direct relationship between PoLTT at 20 minutes after lens insertion and out-in time (P = .047). The % change in the PoLTT after 5-hour wear was greater with a thinner initial tear clearance than those with a thicker one (P = .034).

CONCLUSIONS

Within our study parameters, a thinner PoLTT under a small-diameter SL was associated with faster PoLTT mixing. However, there was no relationship between PoLTT and central corneal thickness during 5-hour SL wear.

摘要

意义

本项关于小直径巩膜镜(SLs)的研究表明,短期佩戴巩膜镜后,镜片后泪液厚度(PoLTT)与镜片后泪液混合显著相关,但与中央角膜水肿无关。

目的

本研究旨在探讨佩戴巩膜镜5小时期间,巩膜镜泪液清除率(PoLTT)对中央角膜厚度及镜片后泪液动力学的影响。

方法

对无活动性眼部疾病的新手双侧佩戴巩膜镜(hofocon A;直径15.6毫米;厚度约438微米;Dk值97;折射率1.44),初始PoLTT值范围为74至543微米。佩戴巩膜镜期间,使用光学相干断层扫描测量中央角膜厚度和PoLTT。使用荧光造影和“进出”法评估泪液混合情况。

结果

佩戴巩膜镜5小时后,中央角膜水肿的平均值为1.51%(95%置信区间为1.26%至1.76%;P <.001),在镜片插入后2小时达到峰值(1.65% [95%置信区间为1.45%至1.85%]),且与PoLTT无关。在镜片上方观察到镜片后泪膜的荧光衰减最快。除上方外,所有象限的荧光衰减率从中心到周边均增加。在镜片插入后20分钟和5小时佩戴时,PoLTT与荧光衰减率之间均呈负相关(P <.05)。排除“进出”时间超过5分钟的观察结果后,我们发现镜片插入后20分钟时的PoLTT与“进出”时间呈正相关(P = 0.047)。初始泪液清除率较薄时,佩戴5小时后PoLTT的变化百分比大于较厚时(P = 0.034)。

结论

在我们的研究参数范围内,小直径巩膜镜下较薄的PoLTT与更快的PoLTT混合相关。然而,佩戴巩膜镜5小时期间,PoLTT与中央角膜厚度之间无相关性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验