Otten Henny M, van der Linden Bart J J J, Visser Esther-Simone
NKL Contactlenzen, Emmen, The Netherlands *
Visser Contact Lens Practice, Nijmegen-Utrecht, The Netherlands.
Optom Vis Sci. 2018 Jun;95(6):515-522. doi: 10.1097/OPX.0000000000001228.
New bitangential mini-scleral lens designs provide a highly precise fit, follow the scleral shape, are comfortable to wear, and can correct residual astigmatism. This new scleral lens design complements the arsenal of medical contact lenses available to eye care practitioners.
The aim of this study was to evaluate the subjective and objective performance of a new mini-scleral lens design with a bitangential periphery.
In this observational study, data were collected for up to 15 months (median, 84 days; interquartile range, 76 days) from the left eyes of 133 patients fitted with this newly designed lens. Data were recorded during regular visits at Visser Contact Lens Practice's scleral lens clinics: diagnosis, clinical indication for scleral lenses, previous contact lens type, subjective performance, horizontal visible iris diameter, corrected distance visual acuity, and scleral lens fitting characteristics.
The most common indication was keratoconus (45%), followed by irregular astigmatism (22%), keratoplasty (16.5%), ocular surface disease (13.5%), and other forms of irregular astigmatism (3%). The majority of patients (79%) scored comfort as either a 4 or 5 (out of 5), and 82% wore their lenses 12 hours or longer a day. Most lenses (81%) had a diameter of 16 mm (median, 16 mm; range, 15.5 to 17 mm) and were composed of Boston XO2 (46%), Menicon Z (44%), Boston XO (9%), or Boston Equalens II (1%). The median corrected distance visual acuity was 0.022 logarithm of the minimal angle of resolution (interquartile range, 0.155). The fitting characteristics revealed optimal values for centration and movement in 91% and 83%, respectively. Finally, the median stabilization axis was 50 degrees.
New mini-scleral lenses with bitangential peripheral geometry yield satisfactory clinical results and good subjective performance and are therefore an effective option for managing patients who have irregular astigmatism or other corneal pathology.
新型双切向微型巩膜镜设计提供了高度精确的贴合度,能贴合巩膜形状,佩戴舒适,且可矫正残余散光。这种新型巩膜镜设计完善了眼科护理从业者可用的医用隐形眼镜种类。
本研究旨在评估一种新型带双切向周边的微型巩膜镜设计的主观和客观性能。
在这项观察性研究中,收集了133例佩戴这种新设计镜片的患者左眼长达15个月的数据(中位数为84天;四分位间距为76天)。数据记录于维瑟隐形眼镜诊所的巩膜镜定期就诊期间:诊断、巩膜镜的临床适应症、先前的隐形眼镜类型、主观性能、水平可见虹膜直径、矫正远视力以及巩膜镜的适配特征。
最常见的适应症是圆锥角膜(45%),其次是不规则散光(22%)、角膜移植术(16.5%)、眼表疾病(13.5%)以及其他形式的不规则散光(3%)。大多数患者(79%)将舒适度评为4或5(满分5分),82%的患者每天佩戴镜片12小时或更长时间。大多数镜片(81%)直径为16毫米(中位数为16毫米;范围为15.5至17毫米),由波士顿XO2(46%)、美尼康Z(44%)、波士顿XO(9%)或波士顿Equalens II(1%)制成。矫正远视力的中位数为最小分辨角对数的0.022(四分位间距为0.155)。适配特征显示,分别有91%和83%的镜片在中心定位和移动方面具有最佳值。最后,稳定轴的中位数为50度。
具有双切向周边几何形状的新型微型巩膜镜产生了令人满意的临床结果和良好的主观性能,因此是管理患有不规则散光或其他角膜病变患者的有效选择。