Suppr超能文献

在数分钟内检测血浆中的 MMP-9。揭示一些线索,以开发快速而简单的电化学磁免疫传感器。

Detection of plasma MMP-9 within minutes. Unveiling some of the clues to develop fast and simple electrochemical magneto-immunosensors.

机构信息

Diagnostic Nanotools Group, Cibbim-Nanomedicine, Vall Hebron Research Institute (VHIR), Universitat Autònoma de Barcelona, Barcelona, Spain.

Diagnostic Nanotools Group, Cibbim-Nanomedicine, Vall Hebron Research Institute (VHIR), Universitat Autònoma de Barcelona, Barcelona, Spain; Laboratory of Biophysics, Faculty of Medicine of Monastir, University of Monastir, Tunisia.

出版信息

Biosens Bioelectron. 2018 Sep 15;115:45-52. doi: 10.1016/j.bios.2018.05.020. Epub 2018 May 11.

Abstract

Magnetic beads (MB) have been extensively used to produce sensitive and efficient electrochemical magneto-immunosensors. However, MB effective handling requires training, and MB washing after each incubation step is time consuming and contributes to raise result variability. Consequently, most of the electrochemical magneto-immunosensors reported to date, which entailed relatively long and complex multi-step procedures, would be difficult to carry out at point-of-care (POC) settings or by laypersons. For this reason, here we targeted the development of a simplified detection path, which is fast and simple enough to be operated at a POC setting, sufficiently efficient to provide analyte quantitation comparable to classical diagnostic methods, and dependent on minimal technical requirements to facilitate method global exploitation. As a proof-of-concept, we optimized an extremely simple, fast and efficient electrochemical magneto-immunosensor for detection of matrix metalloproteinase 9 (MMP-9). To accomplish this, we optimized MB immunomodification, produced an immunomodified Poly-HRP signal amplifier, developed a single-step magneto-immunoassay, and optimized electrochemical detection using a multiplexed magnetic holder and a ready-to-use commercial substrate solution. The sensor was finally calibrated by detecting MMP-9 in clinical samples. This electrochemical magneto-immunosensor detected MMP-9 in just 12-15 min, displaying linear response between 0.03 and 2 ng mL of MMP-9, limits of detection (LOD) and quantification (LOQ) of 13 pg mL and 70 pg mL, respectively, %CV< 6%, and accurate quantification of MMP-9 in patient plasma samples. These results were comparable to those afforded by a 5-h reference ELISA that used the same antibodies, confirming the applicability of our simplified method.

摘要

磁珠 (MB) 已被广泛用于制备灵敏高效的电化学磁免疫传感器。然而,MB 的有效处理需要经过培训,并且在每个孵育步骤后进行 MB 洗涤既耗时又会导致结果变异性增加。因此,迄今为止报道的大多数电化学磁免疫传感器都需要相对较长和复杂的多步程序,难以在即时检测 (POC) 环境或非专业人员中进行。出于这个原因,我们旨在开发一种简化的检测途径,该途径足够快速和简单,可以在 POC 设置下进行操作,具有足够的效率,可以提供与经典诊断方法相当的分析物定量,并且依赖于最小的技术要求来促进方法的全球应用。作为概念验证,我们针对检测基质金属蛋白酶 9 (MMP-9) 优化了一种极其简单、快速和高效的电化学磁免疫传感器。为此,我们优化了 MB 的免疫修饰,制备了免疫修饰的多过氧化物酶信号放大器,开发了一步式磁免疫分析,并使用多路复用磁座和即用型商业衬底溶液优化了电化学检测。最后,通过检测临床样本中的 MMP-9 对传感器进行了校准。该电化学磁免疫传感器仅需 12-15 分钟即可检测 MMP-9,在 0.03 至 2ng/mL MMP-9 之间呈现线性响应,检测限 (LOD) 和定量限 (LOQ) 分别为 13pg/mL 和 70pg/mL,CV%<6%,并且可以准确定量患者血浆样本中的 MMP-9。这些结果与使用相同抗体的 5 小时参考 ELISA 相当,证实了我们简化方法的适用性。