Suppr超能文献

对乙二醇双(2-氨基乙基醚)四乙酸(EGTA)与质子和包括钙在内的二价离子的化学计量和表观亲和常数进行电位测量。

Potentiometric measurements of stoichiometric and apparent affinity constants of EGTA for protons and divalent ions including calcium.

作者信息

Smith G L, Miller D J

出版信息

Biochim Biophys Acta. 1985 May 8;839(3):287-99. doi: 10.1016/0304-4165(85)90011-x.

Abstract

The stoichiometric affinity constants of H+, Ca2+, Mg2+ and Sr+ for the ligand EGTA were determined using a modified version of the pH metric method developed by Moisescu and Pusch (Moisescu, D.G. and Pusch, H. (1975) Pfluegers Arch. 355, 243). The values obtained were slightly higher than those previously published. In addition, the shift in the H+ and Ca2+ stoichiometric constants with ionic strength was found to fit an empirical relationship if the total ionic content of the titration solutions was measured in terms of ionic equivalents, Ie (Johansson, L. (1975) Acta Chem. Scand. A29, 365-373), rather than the formal ionic strength, If. Finally, the apparent affinity of EGTA for Ca2+ ions was measured using an abbreviated form of the titration technique. The measured apparent affinity constant agreed with published results only if calculated with respect to pH (measured) of 7.0, rather than pH (concentration).

摘要

使用Moisescu和Pusch开发的pH滴定法的改进版本,测定了H⁺、Ca²⁺、Mg²⁺和Sr⁺与配体乙二醇双(2-氨基乙基醚)四乙酸(EGTA)的化学计量亲和常数(Moisescu, D.G.和Pusch, H. (1975) Pfluegers Arch. 355, 243)。得到的值略高于先前发表的值。此外,如果滴定溶液的总离子含量以离子当量Ie(Johansson, L. (1975) Acta Chem. Scand. A29, 365 - 373)来衡量,而非形式离子强度If,则发现H⁺和Ca²⁺化学计量常数随离子强度的变化符合经验关系。最后,使用滴定技术的简化形式测量了EGTA对Ca²⁺离子的表观亲和力。只有相对于7.0的pH(测量值)而非pH(浓度)进行计算时,测得的表观亲和常数才与已发表的结果一致。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验