Smith G L, Miller D J
Biochim Biophys Acta. 1985 May 8;839(3):287-99. doi: 10.1016/0304-4165(85)90011-x.
The stoichiometric affinity constants of H+, Ca2+, Mg2+ and Sr+ for the ligand EGTA were determined using a modified version of the pH metric method developed by Moisescu and Pusch (Moisescu, D.G. and Pusch, H. (1975) Pfluegers Arch. 355, 243). The values obtained were slightly higher than those previously published. In addition, the shift in the H+ and Ca2+ stoichiometric constants with ionic strength was found to fit an empirical relationship if the total ionic content of the titration solutions was measured in terms of ionic equivalents, Ie (Johansson, L. (1975) Acta Chem. Scand. A29, 365-373), rather than the formal ionic strength, If. Finally, the apparent affinity of EGTA for Ca2+ ions was measured using an abbreviated form of the titration technique. The measured apparent affinity constant agreed with published results only if calculated with respect to pH (measured) of 7.0, rather than pH (concentration).
使用Moisescu和Pusch开发的pH滴定法的改进版本,测定了H⁺、Ca²⁺、Mg²⁺和Sr⁺与配体乙二醇双(2-氨基乙基醚)四乙酸(EGTA)的化学计量亲和常数(Moisescu, D.G.和Pusch, H. (1975) Pfluegers Arch. 355, 243)。得到的值略高于先前发表的值。此外,如果滴定溶液的总离子含量以离子当量Ie(Johansson, L. (1975) Acta Chem. Scand. A29, 365 - 373)来衡量,而非形式离子强度If,则发现H⁺和Ca²⁺化学计量常数随离子强度的变化符合经验关系。最后,使用滴定技术的简化形式测量了EGTA对Ca²⁺离子的表观亲和力。只有相对于7.0的pH(测量值)而非pH(浓度)进行计算时,测得的表观亲和常数才与已发表的结果一致。