Suppr超能文献

流动注射质谱法高通量定量分析食品模拟物中的季铵阳离子

High Throughput Quantification of Quaternary Ammonium Cations in Food Simulants by Flow-Injection Mass Spectrometry.

作者信息

Yu Longjiao, Malik Sargun, Duncan Timothy V, Jablonski Joseph E

机构信息

Illinois Institute of Technology, Department of Food Science and Nutrition, Bedford Park, IL.

U.S. Food and Drug Administration, Center for Food Safety and Applied Nutrition, Bedford Park, IL.

出版信息

J AOAC Int. 2018 Nov 1;101(6):1873-1880. doi: 10.5740/jaoacint.18-0091. Epub 2018 May 31.

Abstract

A flow-injection MS (FI/MS) method was evaluated for the quantitation of quaternary ammonium cations (QACs) in simple food simulants. The calibration standard was dimethyldioctadecyl ammonium ion (C18-C18), and the internal standard was benzyldimethylhexadecyl (BDMHD) ammonium ion. Calibration standards based on the C18-C18 ion were prepared in ethanol with a range of 5 to 500 ppb and contained 100 ppb BDMHD. The mobile phase was 90 + 10 (v/v) acetonitrile-5 mM aqueous ammonium acetate and flowed directly into an electrospray source of the mass spectrometer. Detection was accomplished by single ion recording (SIR) in positive mode. Calibration curves were linear with coefficients of determination above 0.995, and the LOQ was 5 ppb. Recoveries of four QACs derived from Arquad 2HT-75, a commercially available surfactant, were measured in common food simulants: ethanol, water, 10% (v/v) ethanol in water, and 3% (v/v) aqueous acetic acid. A solvent exchange procedure was employed for the three aqueous solvents, which included complete evaporation of the sample followed by reconstitution in ethanol prior to injection. The solvent exchange method minimized losses because of QAC adsorption on glass surfaces. Recoveries ranged from 74.4 ± 4.0 to 106.7 ± 6.6% for the two most abundant Arquad 2HT-75 component cations, dimethyldioctadecyl ammonium and dimethyloctadecyl-hexadecyl ammonium. This method is suitable to quantify trace levels of QACs in food simulants as part of exposure evaluations related to their use in emerging food contact materials.

摘要

对一种流动注射质谱(FI/MS)方法进行了评估,用于定量简单食品模拟物中的季铵阳离子(QACs)。校准标准物为二甲基二辛基铵离子(C18-C18),内标物为苄基二甲基十六烷基(BDMHD)铵离子。基于C18-C18离子的校准标准物在乙醇中制备,范围为5至500 ppb,并含有100 ppb BDMHD。流动相为90 + 10(v/v)乙腈-5 mM乙酸铵水溶液,直接流入质谱仪的电喷雾源。检测通过正模式下的单离子记录(SIR)完成。校准曲线呈线性,决定系数高于0.995,定量限为5 ppb。在常见食品模拟物中测量了源自市售表面活性剂Arquad 2HT-75的四种QACs的回收率:乙醇、水、10%(v/v)乙醇水溶液和3%(v/v)乙酸水溶液。对三种水性溶剂采用了溶剂交换程序,包括样品完全蒸发,然后在进样前用乙醇复溶。溶剂交换方法将由于QAC吸附在玻璃表面而导致的损失降至最低。对于两种含量最高的Arquad 2HT-75组分阳离子,二甲基二辛基铵和二甲基十八烷基-十六烷基铵,回收率范围为74.4 ± 4.0%至106.7 ± 6.6%。作为与新兴食品接触材料中QACs使用相关的暴露评估的一部分,该方法适用于定量食品模拟物中痕量水平的QACs。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验