A method for simultaneous quantitative determination of alkyl benzyl, dialkyl and trialkyl quaternary ammonium compounds (QACs) has been developed, validated and subsequently applied to real water samples in Austria. The method employs liquid-liquid extraction (LLE) followed by liquid chromatography/tandem mass spectrometry (LC-MS/MS), using electrospray ionization (ESI) in positive mode. The overall method quantification limits range from 4 to 19ng/L for the enrichment of 500mL water samples and analyte recoveries are between 80 and 99%. The method was applied to 62 of the respective water samples without filtration to avoid the loss of the analytes due to the high adsorption capacity of these compounds. Maxima in the mg/L range, especially in the wastewater of hospitals and laundries, could be detected for the selected target compounds.
已开发、验证了一种同时定量测定烷基苄基、二烷基和三烷基季铵化合物(QACs)的方法,并随后将其应用于奥地利的实际水样中。该方法采用液液萃取(LLE),然后进行液相色谱/串联质谱(LC-MS/MS)分析,采用正模式电喷雾电离(ESI)。对于500mL水样的富集,该方法的总定量限为4至19ng/L,分析物回收率在80%至99%之间。该方法应用于62个相应的水样,无需过滤,以避免由于这些化合物的高吸附能力导致分析物损失。对于选定的目标化合物,可以检测到毫克/升范围内的最大值,特别是在医院和洗衣店的废水中。