使用不锈钢锉和镍钛锉对两种电子根尖定位仪在确定工作长度方面的准确性进行的体内比较。

An in vivo comparison of accuracy of two electronic apex locators in determining working length using stainless steel and nickel titanium files.

作者信息

Chaudhary Sanjeeb, Gharti Archana, Adhikari Bhawana

机构信息

Department of Conservative Dentistry and Endodontics, School of Dental Sciences, Chitwan Medical College, Bharatpur, Nepal.

出版信息

Clin Cosmet Investig Dent. 2018 May 22;10:75-82. doi: 10.2147/CCIDE.S158882. eCollection 2018.

Abstract

PURPOSE

A key factor affecting the success of endodontic treatment is correct determination of root canal working length (WL). The purpose of this in vivo study was to compare the accuracy of Propex II and iPex II electronic apex locator (EAL) in determining the WL under clinical conditions, to that of radiographic working length (RWL) using stainless steel (SS) and nickel-titanium (NiTi) hand files.

PATIENTS AND METHODS

Thirty-seven patients, with 60 anterior teeth (60 canals) scheduled for endodontic treatment participated in this study after ethical approval. Electronic working length (EWL) was determined by the Propex II and iPex II according to manufacturer's instructions using SS Hand K-files and NiTi Hand files. RWL was determined after EWL determination. The results obtained with each EAL with SS and NiTi files were compared with RWL. Data was analyzed statistically at a significance level of < 0.05. Interclass correlation coefficient was calculated.

RESULTS

Statistical analysis revealed no significant difference between the EALs, indicating similar accuracies between them with respect to accuracy in determining the WL ( > 0.05). No significant difference was found between the EWL and RWL and between SS and NiTi files for WL determination ( > 0.05) as well. The result also displayed a high intraclass correlation coefficient between the RWL and EWL measurement methods.

CONCLUSION

Under the in vivo clinical conditions of this study, both Propex II and iPex II were similar to the RWL determination technique showing high correlation to RWL. Both are clinically acceptable EAL for WL determination and both SS hand K-file and NiTi file can be used interchangeably without compromising the WL during treatment.

摘要

目的

影响根管治疗成功的一个关键因素是正确确定根管工作长度(WL)。本体内研究的目的是比较Propex II和iPex II电子根尖定位仪(EAL)在临床条件下确定WL的准确性与使用不锈钢(SS)和镍钛(NiTi)手动锉的放射学工作长度(RWL)的准确性。

患者与方法

37例计划进行根管治疗的患者(60颗前牙,60个根管)在获得伦理批准后参与了本研究。使用SS手用K锉和NiTi手用锉,按照制造商的说明,通过Propex II和iPex II确定电子工作长度(EWL)。在确定EWL后确定RWL。将每种EAL使用SS和NiTi锉获得的结果与RWL进行比较。数据在显著性水平<0.05下进行统计学分析。计算组内相关系数。

结果

统计分析显示EAL之间无显著差异,表明它们在确定WL的准确性方面相似(>0.05)。在确定WL时,EWL与RWL之间以及SS和NiTi锉之间也未发现显著差异(>0.05)。结果还显示RWL和EWL测量方法之间具有较高的组内相关系数。

结论

在本研究的体内临床条件下,Propex II和iPex II均与RWL确定技术相似,与RWL具有高度相关性。两者都是临床上可接受的用于确定WL的EAL,并且SS手用K锉和NiTi锉均可互换使用,在治疗过程中不会影响WL。

相似文献

8
Apexoconnection: A Novel Technique to Determine Working Length.根尖连接:一种确定工作长度的新技术。
Clin Cosmet Investig Dent. 2021 Aug 17;13:353-360. doi: 10.2147/CCIDE.S316839. eCollection 2021.

引用本文的文献

5
Apexoconnection: A Novel Technique to Determine Working Length.根尖连接:一种确定工作长度的新技术。
Clin Cosmet Investig Dent. 2021 Aug 17;13:353-360. doi: 10.2147/CCIDE.S316839. eCollection 2021.

本文引用的文献

4
Clinical efficacy of electronic apex locators: systematic review.电子根尖定位仪的临床疗效:系统评价
J Endod. 2014 Jun;40(6):759-77. doi: 10.1016/j.joen.2014.03.011. Epub 2014 May 2.
10
An in vivo radiographic evaluation of the accuracy of Apex and iPex electronic Apex locators.
Braz Dent J. 2012;23(1):54-8. doi: 10.1590/s0103-64402012000100010.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验