Maguire G A, Price C P
Ann Clin Biochem. 1985 Mar;22 ( Pt 2):204-10. doi: 10.1177/000456328502200218.
A continuous monitoring spectrophotometric method for the measurement of angiotensin-converting enzyme in human serum is described. It is based on the hydrolysis of furylacrylylphenylalanylglycylglycine and applied to an IL Multistat III centrifugal analyser. The method offers better precision and freedom from interference than a fluorimetric assay we have previously described.
本文描述了一种用于测量人血清中血管紧张素转换酶的连续监测分光光度法。该方法基于呋喃丙烯酰苯丙氨酰甘氨酰甘氨酸的水解,并应用于IL Multistat III离心分析仪。与我们之前描述的荧光分析法相比,该方法具有更高的精密度且不受干扰。