PURPOSE

To evaluate the long-term effect of glistenings and surface light scattering of intraocular lenses (IOLs) on visual and optical performance after cataract surgery.

METHODS

Pseudophakic eyes that underwent standard phacoemulsification and two types of hydrophobic acrylic spherical IOL implantation without complications for at least 5 years were included in this retrospective study. Participants were divided into the glistenings, surface light scattering, and control groups according to the current condition of the IOLs. Then participants received a follow-up examination including uncorrected and corrected distance visual acuity (UDVA and CDVA), contrast sensitivity, straylight, and intraocular higher order aberrations, as well as point spread function (PSF) and modulation transfer function (MTF).

RESULTS

A total of 140 eyes were included in the study. UDVA, CDVA, and glare sensitivity were not significantly different among the three groups (P > .05). However, compared with the control group, the IOLs of the glistenings and surface light scattering groups were associated with significantly lower contrast sensitivity under no glare conditions. Furthermore, eye with glistenings exhibited the highest straylight value (P < .05), whereas no difference was found between the surface light scattering and control groups. In contrast to the control group, the spherical aberration increased and the mean values of PSF and MTF decreased in the glistenings and surface light scattering groups.

CONCLUSIONS

Both glistenings and surface light scattering tend to impair subjective visual performance, such as contrast sensitivity, and potentially affect objective optical quality, including straylight, spherical aberration, PSF, and MTF. [J Refract Surg. 2018;34(6):372-378.].

摘要

目的

评估人工晶状体(IOL)的闪光和表面光散射对白内障手术后视觉和光学性能的长期影响。

方法

本回顾性研究纳入了接受标准超声乳化白内障吸除术并植入两种类型的疏水丙烯酸酯球形IOL且至少5年无并发症的假晶状体眼。根据IOL的当前状况,将参与者分为闪光组、表面光散射组和对照组。然后参与者接受了包括未矫正和矫正远视力(UDVA和CDVA)、对比敏感度、杂散光和眼内高阶像差,以及点扩散函数(PSF)和调制传递函数(MTF)的随访检查。

结果

本研究共纳入140只眼。三组之间的UDVA、CDVA和眩光敏感度无显著差异(P>.05)。然而,与对照组相比,闪光组和表面光散射组的IOL在无眩光条件下的对比敏感度显著降低。此外,有闪光的眼睛杂散光值最高(P<.05),而表面光散射组和对照组之间未发现差异。与对照组相比,闪光组和表面光散射组的球差增加,PSF和MTF的平均值降低。

结论

闪光和表面光散射均倾向于损害主观视觉性能,如对比敏感度,并可能影响客观光学质量,包括杂散光、球差、PSF和MTF。[《屈光手术杂志》。2018;34(6):372 - 378。]