Department of Ophthalmology, Péterfy Sándor Hospital and Traumatology Center, Budapest, Hungary.
PLoS One. 2020 Oct 12;15(10):e0240440. doi: 10.1371/journal.pone.0240440. eCollection 2020.
The aim of our case control study was to evaluate the impact of glistening and tear film quality on visual performance after implantation of two different hydrophobic acrylic intraocular lenses (IOLs).
In our retrospective study we included cataract patients operated between January 1, 2011 and December 31, 2012, with follow-up controls between January 2016 and December 2019. Z-Flex 860FAB (Medicontur) and AcrySof IQ SN60WF (Alcon) monofocal IOLs were implanted during standard phacoemulsification. Best corrected distance visual acuity (BCDVA) and contrast sensitivity were monitored over the post-operative period of up to 6 years. Glistening was evaluated semi-quantitatively with slit-lamp biomicroscopy and quantitatively using Pentacam HR (Oculus). Using HD Analyzer OQAS (Visiometrics), total intraocular light diffusion was interpreted with the objective scatter index (OSI) and tear film quality was evaluated with the tear film related objective scatter index (TF-OSI).
26 eyes implanted with the Z-Flex and 25 eyes with the AcrySof IQ IOLs were included in the analysis. The slit-lamp evaluation of patients with the Z-Flex IOL (0.57 ± 0.60) revealed significantly less glistening (p<0.0001), compared to the AcrySof IQ group (1.82 ± 0.90), and these observations were confirmed by the Pentacam HR analyses, as well (Z-Flex group: 35.1 ± 1.63, Acrysof IQ: 39.6 ± 3.69, p<0.0001). TF-OSI differed between the two sets of patients remarkably (1.53 ± 1.03 vs. 2.51 ± 1.76 for AcrySof IQ and Z-Flex groups, respectively, p = 0.043). Both groups of patients provided similar results of BCDVA and contrast sensitivity.
Glistening and tear film quality both contribute to visual performance outcomes after cataract surgery. In our study the advantage of less glistening in the Z-Flex IOL might have been masked by the adverse effects of the more pronounced tear film insufficiency of these patients, compared to the AcrySof IQ group. Among other factors, tear film quality should also be taken into consideration when comparing the impact of glistening on visual quality of patients implanted with different IOLs.
本病例对照研究旨在评估两种不同疏水性丙烯酸人工晶状体(IOL)植入术后泪膜质量和闪光对视觉表现的影响。
我们的回顾性研究纳入了 2011 年 1 月 1 日至 2012 年 12 月 31 日期间接受手术的白内障患者,并于 2016 年 1 月至 2019 年 12 月进行随访对照。术中使用 MedContur 的 Z-Flex 860FAB 和 Alcon 的 AcrySof IQ SN60WF 单焦点 IOL 进行标准超声乳化白内障吸除术。术后长达 6 年的时间内,监测最佳矫正远视力(BCDVA)和对比敏感度。使用裂隙灯生物显微镜对闪光进行半定量评估,使用 Pentacam HR(Oculus)进行定量评估。使用 HD Analyzer OQAS(Visiometrics),通过客观散射指数(OSI)解释总眼内光散射,并通过泪膜相关客观散射指数(TF-OSI)评估泪膜质量。
纳入了 26 只眼植入 Z-Flex IOL 和 25 只眼植入 AcrySof IQ IOL 的患者进行分析。Z-Flex IOL 组患者的裂隙灯评估结果(0.57±0.60)显示,闪光明显少于 AcrySof IQ 组(1.82±0.90)(p<0.0001),Pentacam HR 分析结果也证实了这一点(Z-Flex 组:35.1±1.63,Acrysof IQ:39.6±3.69,p<0.0001)。两组患者的 TF-OSI 差异显著(AcrySof IQ 组和 Z-Flex 组分别为 1.53±1.03 和 2.51±1.76,p=0.043)。两组患者的 BCDVA 和对比敏感度结果相似。
闪光和泪膜质量都会影响白内障手术后的视觉效果。在我们的研究中,与 AcrySof IQ 组相比,Z-Flex IOL 较少的闪光可能被这些患者更明显的泪膜不足的不利影响所掩盖。在其他因素中,在比较不同 IOL 植入患者的闪光对视觉质量的影响时,还应考虑泪膜质量。