Suppr超能文献

以及疏水性三焦点人工晶状体表面变白的分析。

and analyses of surface whitening in hydrophobic trifocal intraocular lenses.

作者信息

Cabanás Margarita, Navalón Jorge, Luchena Rafael, Lee William, Cerviño Alejandro

机构信息

Clínica Baviera Sevilla, Sevilla, Spain.

Department of Ophthalmology, Hospital Virgen del Rocío, Sevilla, Spain.

出版信息

Front Med (Lausanne). 2025 Mar 18;12:1518707. doi: 10.3389/fmed.2025.1518707. eCollection 2025.

Abstract

INTRODUCTION

Transparency loss due to the whitening of trifocal hydrophobic intraocular lenses (IOLs) is a rare but poorly understood phenomenon. This study investigates its characteristics, underlying mechanisms, and clinical impact to determine its relevance for patient care.

METHODS

A clinical and laboratory analysis was conducted on affected IOLs. Two patients with bilateral trifocal IOL implantation, where one eye exhibited whitening, underwent visual performance testing, light distortion assessment, optical coherence tomography, Scheimpflug imaging, and patient-reported outcome evaluations. An explanted IOL was examined using microscopic and optical bench methods, and attempts were made to replicate the whitening process using unused control lenses.

RESULTS

Clinical findings showed that IOL whitening had minimal impact on visual acuity and light distortion, with no significant impairment reported in patient-reported outcomes. Imaging and laboratory analysis suggested that whitening is caused by subsurface nanoglistening (SSNG), a previously unreported phenomenon in this IOL material. The modulation transfer function of the affected IOLs remained comparable to control lenses, and attempts to induce whitening were unsuccessful.

DISCUSSION

This study provides the first evidence of SSNG in this hydrophobic IOL material, demonstrating that while whitening can occur, its clinical significance is generally low. Given the predominantly subjective nature of symptoms, management should be individualized, with explantation decisions made in close consultation with the patient. These findings contribute to a better understanding of IOL material stability and patient counseling in cases of transparency loss.

摘要

引言

三焦点疏水人工晶状体(IOL)变白导致的透明度丧失是一种罕见但了解甚少的现象。本研究调查其特征、潜在机制和临床影响,以确定其对患者护理的相关性。

方法

对受影响的人工晶状体进行临床和实验室分析。两名接受双侧三焦点人工晶状体植入的患者,其中一只眼睛出现变白,接受了视觉性能测试、光畸变评估、光学相干断层扫描、Scheimpflug成像和患者报告结局评估。使用显微镜和光具座方法检查取出的人工晶状体,并尝试使用未使用的对照晶状体复制变白过程。

结果

临床发现表明,人工晶状体变白对视力和光畸变影响最小,患者报告结局中未报告有明显损害。成像和实验室分析表明,变白是由表面下纳米闪烁(SSNG)引起的,这是这种人工晶状体材料中以前未报告的现象。受影响的人工晶状体的调制传递函数与对照晶状体相当,诱导变白的尝试未成功。

讨论

本研究提供了这种疏水人工晶状体材料中存在SSNG的首个证据,表明虽然可能会发生变白,但其临床意义通常较低。鉴于症状主要为主观性,管理应个体化,在与患者密切协商后做出取出决定。这些发现有助于更好地理解人工晶状体材料稳定性以及透明度丧失情况下的患者咨询。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/48a4/11958987/9a16af77014d/fmed-12-1518707-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验