OBJECTIVE

To examine the relationship between extended high-frequency pure tone hearing thresholds (frequencies 10 to 14 kHz) and working memory capacity (WMC), inhibitory control, and cognitive flexibility.

DESIGN

Experimental study measuring correlations between different high-frequency hearing threshold measures and cognitive measures.

STUDY

Pure tone audiometry was assessed in the extended high-frequency (frequencies 10, 12.5 and 14 kHz). Subjects were also tested regarding WMC, inhibitory control (response inhibition), and cognitive flexibility (information updating and shifting ability).

SAMPLE

Forty-three subjects between 20 and 29 years old with normal hearing (≤ 20 dB HL) in the frequency range between 0.125 to 8 kHz.

RESULTS

No significant correlations were seen between high-frequency hearing thresholds defined as average best and worst ear high-frequency hearing thresholds and the cognitive measures. Differences between the best and the worst ear showed significant negative correlations with inhibitory control and global executive function (combination score for WMC, inhibitory control and cognitive flexibility).

CONCLUSIONS

The present study suggests that global executive functions, more specifically response inhibition, and hearing threshold asymmetry in the extended high-frequency range are interrelated.

摘要

目的

研究扩展高频纯音听力阈值(频率10至14千赫)与工作记忆容量(WMC)、抑制控制和认知灵活性之间的关系。

设计

实验研究,测量不同高频听力阈值测量值与认知测量值之间的相关性。

研究

在扩展高频范围(频率10、12.5和14千赫)进行纯音听力测定。还对受试者的工作记忆容量、抑制控制(反应抑制)和认知灵活性(信息更新和转换能力)进行了测试。

样本

43名年龄在20至29岁之间、在0.125至8千赫频率范围内听力正常(≤20分贝听力级)的受试者。

结果

定义为平均最佳和最差耳高频听力阈值的高频听力阈值与认知测量值之间未发现显著相关性。最佳耳和最差耳之间的差异与抑制控制和整体执行功能(工作记忆容量、抑制控制和认知灵活性的综合得分)呈显著负相关。

结论

本研究表明,扩展高频范围内的整体执行功能,更具体地说是反应抑制,与听力阈值不对称相关。