多滴法检测人眼角膜上皮对荧光素的通透性。

Corneal epithelial permeability to fluorescein in humans by a multi-drop method.

机构信息

School of Optometry, Indiana University, Bloomington, Indiana, United States of America.

Department of Cornea and Refractive Surgery, Sankara Nethralaya, Chennai, India.

出版信息

PLoS One. 2018 Jun 19;13(6):e0198831. doi: 10.1371/journal.pone.0198831. eCollection 2018.

Abstract

PURPOSE

The permeability of the corneal epithelium to fluorescein Pdc is an indicator of the health of the ocular surface. It can be measured in a clinical setting by determining the accumulation of fluorescein in the stroma following administration of the dye on the ocular surface. Here we demonstrate a new multi-drop method for the measurement of Pdc by a spot fluorometer.

METHODS

Twenty-nine healthy participants were recruited for this study. First, a probe-drop of fluorescein (0.35%, 2 μL) was instilled on the conjunctiva. The clearance of the dye from the tears was immediately measured using the fluorometer. Following this, two loading drops (2%; 6 μL each) were administered 10 min apart. Fifteen minutes later, the ocular surface was washed and fluorescence from the stroma Fs was measured. Permeability was calculated using Pdc = (Q x Fs)/ (2 x AUC), where Q is the stromal thickness and AUC is the area under the fluorescence vs. time curve for the loading drops.

RESULTS

After the probe drop, the tear fluorescence followed an exponential decay (elimination rate constant; kd = 0.41 ± 0.28 per min; 49 eyes of 29 subjects), but the increase in Fs was negligible. However, after the loading drops, the measured Fs was ~ 20-fold higher than the autofluorescence and could be recorded at a high signal to noise ratio (SNR > 40). The intra-subject variability of kd was insignificant. Since fluorescein undergoes concentration quenching at > 0.5%, the value of AUC for the loading drops was estimated by scaling the AUC of the probe drop. The calculated Pdc was 0.54 ± 0.54 nm/sec (n = 49). A Monte Carlo simulation of the model for the multi-drop protocol confirmed the robustness of the estimated Pdc.

CONCLUSIONS

The new multi-drop method can be used in place of the single-drop approach. It can overcome a lack of sensitivity in fluorometers of high axial resolution. The Pdc estimated by the multi-drop method is ~ 11-fold higher than previously reported but closer to the value reported for other drugs with equivalent octanol/water partition coefficient.

摘要

目的

角膜上皮对荧光素 Pdc 的通透性是眼表健康的一个指标。它可以通过在眼表面给予染料后,测定染料在基质中的积累来在临床环境中进行测量。在这里,我们展示了一种新的使用点荧光计测量 Pdc 的多滴法。

方法

这项研究招募了 29 名健康参与者。首先,在结膜上滴入一滴荧光素(0.35%,2 μL)探针。立即使用荧光计测量染料从泪液中的清除情况。在此之后,相隔 10 分钟给予两次加载滴(2%,每次 6 μL)。15 分钟后,清洗眼表面并测量基质中的荧光 Fs。使用 Pdc =(Q x Fs)/(2 x AUC)计算通透性,其中 Q 是基质厚度,AUC 是加载滴的荧光随时间变化的曲线下面积。

结果

在探针滴注后,泪液荧光遵循指数衰减(消除速率常数;kd = 0.41 ± 0.28 每分钟;29 名受试者的 49 只眼),但 Fs 的增加可以忽略不计。然而,在加载滴注后,测量的 Fs 比自发荧光高约 20 倍,可以在高信噪比(SNR > 40)下记录。kd 的个体内变异性无显著意义。由于荧光素在 > 0.5%时会发生浓度猝灭,因此通过缩放探针滴注的 AUC 来估计加载滴注的 AUC 值。计算出的 Pdc 为 0.54 ± 0.54 nm/sec(n = 49)。多滴方案模型的蒙特卡罗模拟证实了所估计的 Pdc 的稳健性。

结论

新的多滴法可以替代单滴法。它可以克服高轴向分辨率荧光计的灵敏度不足。多滴法估计的 Pdc 比以前报道的高 11 倍,但更接近具有等效辛醇/水分配系数的其他药物报道的值。