Suppr超能文献

数字化种植体印模与传统种植体印模制取石膏模型的精度比较:一项体外研究。

Accuracy of printed casts generated from digital implant impressions versus stone casts from conventional implant impressions: A comparative in vitro study.

机构信息

Division of Postgraduate Prosthodontics, Tufts University School of Dental Medicine, Boston, Massachusetts.

Department of Public Health and Community Service, Tufts University School of Dental Medicine, Boston, Massachusetts.

出版信息

Clin Oral Implants Res. 2018 Aug;29(8):835-842. doi: 10.1111/clr.13297. Epub 2018 Jun 21.

Abstract

OBJECTIVES

The aim of this in vitro study was to compare the accuracy of printed implant casts from digital impressions with two intra-oral scanners (IOS) to stone casts from conventional impressions. The hypothesis was that printed casts would be more accurate than stone casts from conventional impressions.

MATERIALS AND METHODS

A mandibular stone cast with Kennedy class II edentulism was fabricated using two internal connection tissue-level implants at 30 degrees to each other (Replace Select RP, Nobel Biocare) to serve as master. Digital impressions (n = 10) were made with the white light (WL) and Active Wavefront Sampling technology (AWST) IOS. The resultant standard tessellation language (STL) datasets were used to print implant casts through stereolithography (SLA) prototyping. The conventional casts (n = 10) were produced with splinted open tray impression technique and polyether material in type IV stone. The master cast and all groups were digitized with lab reference scanner. The test groups STL datasets were superimposed to master cast STL in inspection software (Geomagic control 2015) to calculate root-mean-square error.

RESULTS

The conventional, WL IOS and AWST IOS groups had mean values of 53.49 μm (SD 9.47), 108.09 μm (SD 9.59) and 120.39 μm (SD 5.91), respectively. The Shapiro-Wilk test showed no evidence of nonnormality (p = 0.131) and Levene's test showed no evidence of heterogeneity of variance (p = 0.518). The one-way ANOVA demonstrated a statistically significant difference (p < 0.001). Tukey's honest significant difference (HSD) showed statistically significant differences between all groups: for the comparison of AWST IOS and WL IOS, the p-value was 0.009, and the p-values of the other post hoc tests were <0.001.

CONCLUSION

Printed casts generated from digital impressions for partially edentulous posterior mandibular arches had inferior accuracy to conventional stone casts fabricated from splinted open tray impressions. The printed casts from WL IOS had better accuracy compared to AWST IOS.

摘要

目的

本体外研究旨在比较两种口内扫描仪(IOS)与传统印模的数字印模的种植体印模的准确性,假设是打印的印模比传统印模的石印模更准确。

材料和方法

使用两个相互成 30 度角的内部连接组织水平种植体(Replace Select RP,Nobel Biocare)制作下颌骨石模型,作为主模型,以制作 Kennedy 类 II 无牙颌的下颌骨石模型。用白光(WL)和主动波前采样技术(AWST)IOS 进行数字印模(n=10)。所得标准三角测量语言(STL)数据集通过立体光刻(SLA)原型制作用于打印种植体印模。常规印模(n=10)采用夹板开口托盘印模技术和 IV 型石聚醚材料制作。主模型和所有组均用实验室参考扫描仪数字化。测试组的 STL 数据集在检测软件(Geomagic control 2015)中与主模型的 STL 叠加,以计算均方根误差。

结果

常规组、WL IOS 组和 AWST IOS 组的平均值分别为 53.49μm(SD 9.47)、108.09μm(SD 9.59)和 120.39μm(SD 5.91)。Shapiro-Wilk 检验表明无非正态性证据(p=0.131),Levene 检验表明方差无异质性证据(p=0.518)。单因素方差分析显示存在统计学差异(p<0.001)。Tukey 诚实显著差异(HSD)显示所有组之间存在统计学差异:AWST IOS 和 WL IOS 比较的 p 值为 0.009,其他事后检验的 p 值均<0.001。

结论

部分无牙下颌后牙弓的数字印模生成的打印印模的准确性低于夹板开口托盘印模的常规石印模。与 AWST IOS 相比,WL IOS 生成的打印印模具有更好的准确性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验