Suppr超能文献

幼儿圆窗与耳蜗造瘘插入途径电极位置的比较:一项锥形束计算机断层扫描研究

Comparison of electrode position between round window and cochleostomy inserting approaches among young children: a cone-beam computed tomography study.

作者信息

Fan Xintai, Xia Ming, Wang Zhe, Zhang Hui, Liu Chengcheng, Wang Na, Hou Lingxiao, Li Chen, Xu Anting

机构信息

a Department of Otorhinolaryngology & Head and Neck Surgery , The Second Hospital of Shandong University , Jinan , China.

出版信息

Acta Otolaryngol. 2018 Sep;138(9):815-821. doi: 10.1080/00016489.2018.1478127. Epub 2018 Jun 23.

Abstract

BACKGROUND

As the two most commonly used approaches for cochlear implants (CIs), the round-window insertion (RWI) and cochleostomy are still controversial about which approach is optimal. The lack of visual observation methods makes it difficult to compare the electrode position between them.

OBJECTIVES

To evaluate and compare the electrode position between RWI and cochleostomy approaches for CI among young children.

MATERIALS AND METHODS

Twenty-four patients (16 male, 8 female) accepting CI and temporal cone-beam computed tomography (CBCT) scan post-operation in our hospital from January 2016 to July 2017 were analyzed retrospectively. Operative notes and images were used to identify the surgical technique. Mainly depending on the round-window exposure, 15 cochleae were performed with RWI and 11 performed with cochleostomy.

RESULTS

Mean age, 2.4 (range 0.8-7) years. The CBCT images showed that all the electrode arrays were located in scala tympani. There were no significantly statistical differences in the distance between electrode contacts and modiolus (EMI), intracochlear insertion length and the angle of electrode arrays at the insertion site of the cochlea.

CONCLUSIONS AND SIGNIFICANCE

Both approaches could insert electrodes into scala tympani satisfactorily. As electrodes and cochlear structures could be clearly visualized, CBCT can be applied to assess the electrode position reliably.

摘要

背景

作为人工耳蜗植入(CI)最常用的两种方法,圆窗插入法(RWI)和耳蜗造瘘术哪种方法最佳仍存在争议。由于缺乏视觉观察方法,难以比较两者之间的电极位置。

目的

评估和比较幼儿CI中RWI和耳蜗造瘘术两种方法的电极位置。

材料与方法

回顾性分析2016年1月至2017年7月在我院接受CI并术后进行颞部锥形束计算机断层扫描(CBCT)的24例患者(男16例,女8例)。手术记录和图像用于确定手术技术。主要根据圆窗暴露情况,15例耳蜗采用RWI,11例采用耳蜗造瘘术。

结果

平均年龄2.4岁(范围0.8 - 7岁)。CBCT图像显示所有电极阵列均位于鼓阶。电极触点与蜗轴的距离(EMI)、耳蜗内插入长度以及耳蜗插入部位电极阵列的角度均无显著统计学差异。

结论及意义

两种方法均可将电极满意地插入鼓阶。由于电极和耳蜗结构可清晰可视化,CBCT可用于可靠地评估电极位置。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验