Department of Surgical Sciences, Otorhinolaryngology, Head and Neck Surgery, Uppsala University, Uppsala, Sweden.
Ear Hear. 2019 Mar/Apr;40(2):393-400. doi: 10.1097/AUD.0000000000000624.
The purpose of this study was to evaluate the three-dimensional (3D) anatomy and potential damage to the hook region of the human cochlea following various trajectories at cochlear implantation (CI). The goal was to determine which of the approaches can avoid lesions to the soft tissues, including the basilar membrane and its suspension to the lateral wall. Currently, there is increased emphasis on conservation of inner ear structures, even in nonhearing preservation CI surgery.
Micro-computed tomography and various CI approaches were made in an archival collection of macerated and freshly fixed human temporal bones. Furthermore, synchrotron radiation phase-contrast imaging was used to reproduce the soft tissues. The 3D anatomy was investigated using bony and soft tissue algorithms, and influences on inner ear structures were examined.
Micro-computed tomography with 3D rendering demonstrated the topography of the round window (RW) and osseous spiral laminae, while synchrotron imaging allowed reproduction of soft tissues such as the basilar membrane and its suspension around the RW membrane. Anterior cochleostomies and anteroinferior cochleostomies invariably damaged the intracochlear soft tissues while inferior cochleostomies sporadically left inner ear structures unaffected.
Results suggest that cochleostomy approaches often traumatize the soft tissues at the hook region at CI surgery. For optimal structural preservation, the RW approach is, therefore, recommended.
本研究旨在评估不同耳蜗植入(CI)轨迹对人耳蜗钩区的三维(3D)解剖结构和潜在损伤。目标是确定哪种方法可以避免对包括基底膜及其对侧壁的悬挂在内的软组织结构造成损伤。目前,即使在非听力保护 CI 手术中,也越来越强调对内耳结构的保护。
在经过软化和新鲜固定的人颞骨存档标本中进行了微计算机断层扫描和各种 CI 方法,此外,还使用同步辐射相衬成像来复制软组织。使用骨性和软组织算法研究 3D 解剖结构,并检查对内耳结构的影响。
3D 渲染的微计算机断层扫描显示了圆窗(RW)和骨性螺旋板的地形,而同步辐射成像则允许复制基底膜及其在 RW 膜周围的悬挂等软组织。前耳蜗造口术和前下耳蜗造口术不可避免地损伤了耳蜗内的软组织,而下耳蜗造口术则偶尔不会对内耳结构造成影响。
结果表明,CI 手术中的耳蜗造口术方法经常会损伤钩区的软组织。因此,为了实现最佳的结构保护,建议采用 RW 入路。