Suppr超能文献

使用 68 镓标记的生长抑素变体对神经内分泌肺肿瘤相关非钙化结节进行计算机断层扫描研究以改善诊断:一项非实验、非随机、横断面研究。

Computed Tomographic Studies of Noncalcified Nodules Related to Neuroendocrine Lung Tumor Using 68Gallium-Tagged Somatostatin Variant for Improvement in Diagnosis: A Non-Experimental, Non-Randomized, Cross-Sectional Study.

机构信息

Department of Nuclear Medicine, The First Affiliated Hospital of Jiamusi University, Jamusi, Heilongjiang, China (mainland).

Department of Emergency Medicine, The First Affiliated Hospital of Jiamusi University, Jamusi, Heilongjiang, China (mainland).

出版信息

Med Sci Monit. 2018 Jun 30;24:4501-4509. doi: 10.12659/MSM.908545.

Abstract

BACKGROUND 18Fluoro-fluorodeoxyglucose (FDG)- based positron-emission computed tomography (PET) has less specificity for noncalcified nodules (NNs). Somatostatin receptors affect the expression of normal and malignant cells. The purpose of the study was to compare the sensitivity, specificity, and accuracy of 68Gallium-tagged DOTA-octreotate (Ga-tDO) with that of FDG PET for diagnosis of newly detected and/or untreated NNs in lung cancer patients. MATERIAL AND METHODS A total of 45 patients with lung cancer were included in the cross-sectional study and underwent Ga-tDO and FDG PET. We further confirmed observed outcomes by testing immune histochemical staining for subtype 2A of somatostatin receptor in a granuloma tissue array. The chi-square test was performed for sensitivity and specificity of predictive values among the 3 diagnostic modalities. McNemar's test was performed to compare accuracy between Ga-tDO and FDG PET. Results were considered significant at 95% confidence level. RESULTS Ga-tDO had less sensitivity (69% vs. 89%) but more specificity (91% vs. 78%) than FDG PET. Ga-tDO and FDG PET were characterized as 36 and 6 and in 36 and 3 lesions as accurate and inaccurate, respectively. There was an insignificant difference between Ga-tDO and FDG PET regarding diagnostic accuracy (p=0.7). Dosimetry results showed that the lungs were one of the least critically affected organs. CONCLUSIONS Ga-tDO was more specific but less sensitive than FDG PET scanning and imaging.

摘要

背景

18F 氟代脱氧葡萄糖(FDG)正电子发射断层扫描(PET)对非钙化结节(NNs)的特异性较低。生长抑素受体影响正常和恶性细胞的表达。本研究旨在比较 68Ga 标记的 DOTATATE(Ga-tDO)与 FDG PET 对肺癌患者新发现和/或未经治疗的 NNs 的诊断的敏感性、特异性和准确性。

材料与方法

共 45 例肺癌患者进行了横断面研究,接受了 Ga-tDO 和 FDG PET 检查。我们通过测试肉芽肿组织阵列中生长抑素受体 2A 亚型的免疫组织化学染色,进一步证实了观察到的结果。进行了卡方检验,以评估 3 种诊断方法的预测值的敏感性和特异性。McNemar 检验用于比较 Ga-tDO 和 FDG PET 之间的准确性。结果以 95%置信水平被认为具有统计学意义。

结果

Ga-tDO 的敏感性(69%比 89%)较低,但特异性(91%比 78%)较高。Ga-tDO 和 FDG PET 分别有 36 个和 6 个病变为准确,有 36 个和 3 个病变为不准确。Ga-tDO 和 FDG PET 的诊断准确性无显著差异(p=0.7)。剂量学结果显示,肺是受影响最小的器官之一。

结论

Ga-tDO 比 FDG PET 扫描和成像更特异但敏感性较低。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8a8a/6055512/a2f332b6e9ea/medscimonit-24-4501-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验