In hemodialysis patients, lower plasma magnesium (Mg) concentrations are associated with a higher overall and cardiovascular mortality. The optimal concentration appears to be above the reference range for the healthy population. Plasma Mg is not routinely measured after hemodialysis. Aim of this study was to determine the effect of routine hemodialysis on plasma Mg. Plasma Mg was measured in duplicate before (Mg) and after (Mg) dialysis in 6 consecutive hemodialysis sessions of 34 patients using a fixed 0.50 mmol/L dialysate Mg concentration. Mean Mg was 0.88 mmol/L (±0.14) and mean Mg was statistically significantly lower: mean intra-dialytic decline 0.10 mmol/L (95%-CI 0.06-0.13). A 0.10 mmol/L higher Mg was associated with a 0.03 mmol/L higher Mg (95%-CI 0.024-0.037). At a Mg of 0.74 mmol/L, Mg equalled Mg. There was an intra-dialytic decline of plasma Mg at higher Mg values and an increase at lower Mg values. In conclusion, in the majority of the hemodialysis patients, Mg concentrations are in the reference range of the healthy population, which may be too low for hemodialysis patients. Routine hemodialysis with the widely used 0.50 mmol/L dialysate Mg concentration, further declines magnesium in the majority of patients. Current dialysate Mg concentrations may be too low.
在血液透析患者中,较低的血浆镁(Mg)浓度与较高的总死亡率和心血管死亡率相关。最佳浓度似乎高于健康人群的参考范围。血液透析后通常不测量血浆 Mg。本研究的目的是确定常规血液透析对血浆 Mg 的影响。使用固定的 0.50mmol/L 透析液 Mg 浓度,对 34 名患者的 6 个连续血液透析疗程中的每个疗程,在透析前(Mg)和透析后(Mg)分别测量两次血浆 Mg。平均 Mg 为 0.88mmol/L(±0.14),Mg 明显较低:平均透析内下降 0.10mmol/L(95%CI 0.06-0.13)。Mg 升高 0.10mmol/L 与 Mg 升高 0.03mmol/L 相关(95%CI 0.024-0.037)。当 Mg 为 0.74mmol/L 时,Mg 等于 Mg。在较高的 Mg 值时,血浆 Mg 呈透析内下降趋势,而在较低的 Mg 值时,血浆 Mg 呈增加趋势。总之,在大多数血液透析患者中,Mg 浓度处于健康人群的参考范围内,这对于血液透析患者来说可能过低。使用广泛使用的 0.50mmol/L 透析液 Mg 浓度进行常规血液透析,会使大多数患者的镁进一步下降。目前的透析液 Mg 浓度可能过低。