de Oliveira Jorge P P, de Lima J H P, Chong E Silva D C, Medeiros D, Solé D, Wandalsen G F
Federal University of São Carlos (UFSCar), Brazil; Federal University of São Paulo (UNIFESP), Brazil.
Federal University of São Paulo (UNIFESP), Brazil.
Allergol Immunopathol (Madr). 2019 May-Jun;47(3):295-302. doi: 10.1016/j.aller.2018.03.003. Epub 2018 Jul 5.
To review available evidence in the literature on impulse oscillometry in the assessment of lung function in children with respiratory diseases, especially asthma.
Research in the Medline, PubMed, and Lilacs databases, with the keywords forced oscillation, impulse oscillometry, asthma and impulse oscillometry.
The Impulse Oscillometry System (IOS) allows the measurement of resistance and reactance of airways and is used as a diagnostic resource. A significant association between the findings of the IOS and those of spirometry is observed. In asthma, the IOS has already been used to assess the bronchodilator response and the therapeutic response to different drugs and has shown to be a sensitive technique to evaluate disease control. There are limitations to this assessment, such as children with attention deficit and in some cases it is difficult to interpret the results from a clinical point of view.
The IOS is a useful tool for the measurement of the lung function of children. It is an easy test, although its interpretation is not straightforward.
回顾文献中关于脉冲振荡法评估呼吸系统疾病尤其是哮喘儿童肺功能的现有证据。
在Medline、PubMed和Lilacs数据库中进行研究,关键词为强迫振荡、脉冲振荡法、哮喘和脉冲振荡法。
脉冲振荡法系统(IOS)可测量气道阻力和电抗,并用作诊断资源。观察到IOS结果与肺量计结果之间存在显著关联。在哮喘中,IOS已被用于评估支气管扩张剂反应以及对不同药物的治疗反应,并已证明是评估疾病控制的一种敏感技术。这种评估存在局限性,例如注意力缺陷儿童,并且在某些情况下从临床角度难以解释结果。
IOS是测量儿童肺功能的有用工具。它是一项简单的测试,尽管其解释并不直接。