Atrophy of the brain grey matter (GM) is an accepted and important feature of multiple sclerosis (MS). However, its accurate measurement is hampered by various technical, pathological and physiological factors. As a consequence, it is challenging to investigate the role of GM atrophy in the disease process as well as the effect of treatments that aim to reduce neurodegeneration. In this paper we discuss the most important challenges currently hampering the measurement and interpretation of GM atrophy in MS. The focus is on measurements that are obtained in individual patients rather than on group analysis methods, because of their importance in clinical trials and ultimately in clinical care. We discuss the sources and possible solutions of the current challenges, and provide recommendations to achieve reliable measurement and interpretation of brain GM atrophy in MS.
脑灰质(GM)萎缩是多发性硬化症(MS)的一个公认的重要特征。然而,由于各种技术、病理和生理因素的影响,其准确测量受到了阻碍。因此,研究 GM 萎缩在疾病过程中的作用以及旨在减少神经退行性变的治疗效果具有一定的挑战性。本文讨论了目前阻碍 MS 中 GM 萎缩测量和解释的最重要的挑战。重点是讨论在个体患者中获得的测量值,而不是群体分析方法,因为这些方法在临床试验中乃至最终在临床护理中都很重要。我们讨论了当前挑战的来源和可能的解决方案,并提供了在 MS 中实现可靠测量和解释脑 GM 萎缩的建议。