Factors influencing the effective dose associated with CBCT: a systematic review.

机构信息

Department of Orthodontics, Bauru Dental School, Alameda Octávio Pinheiro Brisolla 9-75, Bauru, São Paulo, 17012-901, Brazil.

, Teresina, Piauí, Brazil.

出版信息

Clin Oral Investig. 2019 Mar;23(3):1319-1330. doi: 10.1007/s00784-018-2561-4. Epub 2018 Jul 13.

Abstract

INTRODUCTION

Due to potential impact of the effects of ionizing radiation used in medical and dental examinations on public health in recent years, many studies are being conducted to quantify the radiation dose values, evaluate scanners, and indicate factors that could influence or reduce radiation doses.

OBJECTIVES

This study aimed to evaluate, by a systematic review, the factors that influence the effective radiation dose associated with cone beam computed tomography and respective effects, and compared the effective dose of different cone beam computed tomography (CBCT) scanners with similar exposure parameters.

MATERIALS AND METHODS

A search was conducted on five databases from 2007 to 2015.

RESULTS

The search identified 741 abstracts, among which 44 eligible articles were retrieved in full text. Twenty-three studies met the inclusion criteria and were included. Additional copper filter was evaluated in one study, patient size in 2 studies, region of interest in 1 study, use of a thyroid shield in 2 studies, scan angle in 3 studies, exposure time in 10 studies, FOV diameter in 17 studies, FOV height in 17 studies, kV in 16 studies, mA in 18 studies, mAs in 13 studies, voxel in 8 studies, and resolution in 3 studies. When similar exposure parameters were evaluated, it was observed that CBCT scanner with lower effective dose was Kodak® 9000C 3D (mean 21.2 μSv) in selected studies.

CONCLUSIONS

Thirteen factors were related to changes in the effective dose emitted by different scanners. More studies are needed to identify the image quality requirements in addition to measure the radiation.

CLINICAL RELEVANCE

Studies that give more information for professionals who request and interpret the exams and for technicians who perform 3D images about effective radiation dose associated with CBCT are necessary.

摘要

简介

由于近年来医疗和牙科检查中电离辐射的影响对公众健康的潜在影响,许多研究正在进行中,以量化辐射剂量值,评估扫描仪,并指出可能影响或降低辐射剂量的因素。

目的

本研究通过系统评价评估与锥形束计算机断层扫描相关的有效辐射剂量的影响因素及其影响,并比较具有相似暴露参数的不同锥形束计算机断层扫描(CBCT)扫描仪的有效剂量。

材料和方法

2007 年至 2015 年在五个数据库中进行了搜索。

结果

搜索共确定了 741 个摘要,其中有 44 篇符合条件的文章全文检索。 23 项研究符合纳入标准,并纳入其中。一项研究评估了额外的铜滤器,两项研究评估了患者体型,一项研究评估了感兴趣区域,两项研究评估了使用甲状腺屏蔽,三项研究评估了扫描角度,十项研究评估了曝光时间,十七项研究评估了视场直径,十七项研究评估了视场高度,十六项研究评估了千伏,十八项研究评估了毫安,十三项研究评估了毫安秒,八项研究评估了体素,三项研究评估了分辨率。当评估相似的暴露参数时,观察到具有较低有效剂量的 CBCT 扫描仪是柯达®9000C 3D(平均值 21.2μSv)在选定的研究中。

结论

13 个因素与不同扫描仪发出的有效剂量变化有关。需要更多的研究来确定图像质量要求,除了测量辐射之外。

临床相关性

有必要为要求和解释检查的专业人员以及执行 3D 图像的技术人员提供有关 CBCT 相关有效辐射剂量的更多信息的研究。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验