To evaluate direct drug susceptibility testing on MGIT 960 system for detection of multidrug resistant tuberculosis from smear positive pulmonary specimens.
Cross-sectional analytical study.
Microbiology Department, Armed Forces Institute of Pathology, Rawalpindi, from July 2016 to September 2017.
Smear positive specimens were pretreated according to guidelines and then tested on MGIT 960 TB system for direct drug susceptibility testing (DST) of isoniazid and rifampin. Samples were also processed by gold standard indirect method, which comprises culture and then DST from positive growth by MGIT 960 TB system.
Out of 108 specimens, 95 (88%) DST results were reportable. Out of 95 reportable specimens, 17 isolates were resistant to both isoniazid (INH) and rifampin (RIF) by direct DST. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy for INH were 92%, 93%, 82%, 97% and 92.6%, respectively; and 95%, 96%, 86.3%, 98.6% and 95.7%, respectively for RIF. Average time to report DST by indirect method was 23.6 ±3.9 days, while it was 11.4 ±2.7 days for the direct method.
Direct susceptibility testing on MGIT 960 system showed very good agreement when compared with indirect method. Time saving is crucial factor in initiation of early effective therapy, especially in drug resistant cases. Further studies on large scale are required for more accurate evaluation of this method.
评估在MGIT 960系统上进行直接药敏试验以检测涂片阳性肺部标本中的耐多药结核病。
横断面分析研究。
2016年7月至2017年9月,拉瓦尔品第武装部队病理研究所微生物科。
涂片阳性标本按指南进行预处理,然后在MGIT 960结核系统上进行异烟肼和利福平的直接药敏试验(DST)。样本也采用金标准间接方法处理,即先培养,然后通过MGIT 960结核系统对阳性培养物进行DST。
108份标本中,95份(88%)的DST结果可报告。在95份可报告标本中,通过直接DST,17株分离株对异烟肼(INH)和利福平(RIF)均耐药。INH的敏感性、特异性、阳性预测值、阴性预测值和诊断准确性分别为92%、93%、82%、97%和92.6%;RIF的分别为95%、96%、86.3%、98.6%和95.7%。间接法报告DST的平均时间为23.6±3.9天,而直接法为11.4±2.7天。
与间接法相比,MGIT 960系统上的直接药敏试验显示出很好的一致性。节省时间是开始早期有效治疗的关键因素,尤其是在耐药病例中。需要进行更大规模的进一步研究以更准确地评估该方法。