Suppr超能文献

脐带动脉和胎儿大脑中动脉多普勒指数及脑胎盘比值参考范围:系统综述。

Reference ranges for Doppler indices of umbilical and fetal middle cerebral arteries and cerebroplacental ratio: systematic review.

机构信息

Aragón Institute of Health Research (IIS Aragón), Obstetrics Department, Hospital Clínico Universitario Lozano Blesa, Zaragoza, Spain.

Red de Salud Materno Infantil y del Desarrollo (SAMID), RETICS, Instituto de Salud Carlos III (ISCIII), Subdirección General de Evaluación y Fomento de la Investigación y Fondo Europeo de Desarrollo Regional (FEDER), Spain.

出版信息

Ultrasound Obstet Gynecol. 2019 Apr;53(4):454-464. doi: 10.1002/uog.20102. Epub 2019 Mar 7.

Abstract

OBJECTIVE

To assess studies reporting reference ranges for umbilical artery (UA) and fetal middle cerebral artery (MCA) Doppler indices and cerebroplacental ratio (CPR), using a set of predefined methodological quality criteria for study design, statistical analysis and reporting methods.

METHODS

This was a systematic review of observational studies in which the primary aim was to create reference ranges for UA and MCA Doppler indices and CPR in fetuses of singleton gestations. A search for relevant articles was performed in MEDLINE, EMBASE, CINAHL, Web of Science (from inception to 31 December 2016) and references of the retrieved articles. Two authors independently selected studies, assessed the risk of bias and extracted the data. Studies were scored against a predefined set of independently agreed methodological criteria and an overall quality score was assigned to each study. Linear multiple regression analysis assessing the association between quality scores and study characteristics was performed.

RESULTS

Thirty-eight studies met the inclusion criteria. The highest potential for bias was noted in the following fields: 'ultrasound quality control measures', in which only two studies demonstrated a comprehensive quality-control strategy; 'number of measurements taken for each Doppler variable', which was apparent in only three studies; 'sonographer experience', in which no study on CPR reported clearly the experience or training of the sonographers, while only three studies on UA Doppler and four on MCA Doppler did; and 'blinding of measurements', in which only one study, on UA Doppler, reported that sonographers were blinded to the measurement recorded during the examination. Sample size estimations were present in only seven studies. No predictors of quality were found on multiple regression analysis. Reference ranges varied significantly with important clinical implications for what is considered normal or abnormal, even when restricting the analysis to the highest scoring studies.

CONCLUSIONS

There is considerable methodological heterogeneity in studies reporting reference ranges for UA and MCA Doppler indices and CPR, and the resulting references have important implications for clinical practice. There is a need for the standardization of methodologies for Doppler velocimetry and for the development of reference standards, which can be correctly interpreted and applied in clinical practice. We propose a set of recommendations for this purpose. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.

摘要

目的

使用一套针对研究设计、统计分析和报告方法的预设方法学质量标准,评估报告脐动脉(UA)和胎儿大脑中动脉(MCA)多普勒指数及胎盘-胎儿比值(CPR)参考范围的研究。

方法

这是一项对观察性研究的系统综述,其主要目的是为单胎妊娠胎儿的 UA 和 MCA 多普勒指数及 CPR 建立参考范围。在 MEDLINE、EMBASE、CINAHL、Web of Science(从创建到 2016 年 12 月 31 日)和检索文章的参考文献中进行了相关文章的搜索。两名作者独立选择研究、评估偏倚风险并提取数据。根据一套预先确定的方法学标准对研究进行评分,并为每项研究分配一个整体质量评分。对质量评分与研究特征之间的相关性进行线性多回归分析。

结果

有 38 项研究符合纳入标准。潜在偏倚风险最高的领域为:“超声质量控制措施”,仅有两项研究展示了全面的质量控制策略;“每个多普勒变量的测量次数”,仅在三项研究中可见;“超声医师经验”,CPR 的研究中没有一项明确报告超声医师的经验或培训情况,而 UA 多普勒的三项研究和 MCA 多普勒的四项研究中有此报告;以及“测量的盲法”,仅一项 UA 多普勒研究报告称,超声医师在检查过程中对记录的测量值是盲法的。只有 7 项研究进行了样本量估算。多元回归分析未发现质量的预测因素。参考范围差异显著,对正常或异常的判断有重要的临床意义,即使将分析仅限于评分最高的研究也是如此。

结论

报告 UA 和 MCA 多普勒指数及 CPR 参考范围的研究在方法学上存在很大的异质性,因此得出的参考值对临床实践有重要意义。需要对多普勒血流速度的方法学进行标准化,并制定参考标准,以便在临床实践中正确解释和应用。为此,我们提出了一系列建议。版权所有©2018ISUOG。由 John Wiley & Sons Ltd 出版。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验