Kohmura E, Gürtner P, Holl K, Nemati N, Stoppe G, Lerch K D, Samii M
Rofo. 1986 May;144(5):531-6. doi: 10.1055/s-2008-1048834.
We describe a new non-invasive method for measuring local blood flow in the brain. Xenon (stable)-nl CBF-CT-method has been used in our clinic for the first time in Europe. It is superior to all other methods, such as 133Xenon, SPECT and PET in terms of anatomical accuracy and its resolution. We describe the method and its side effects. Inhalation of Xenon in sub-narcotic doses (33% for five minutes) produced no significant complications. Of 95 examinations, 74 were free of any incidents. The most common side effect was euphoria. The method appears to be suitable for general clinical use.
我们描述了一种测量脑部局部血流的新的非侵入性方法。氙(稳定)-nl脑血流CT方法在欧洲首次在我们诊所使用。在解剖学准确性及其分辨率方面,它优于所有其他方法,如133氙、单光子发射计算机断层扫描(SPECT)和正电子发射断层扫描(PET)。我们描述了该方法及其副作用。吸入亚麻醉剂量的氙(33%,持续五分钟)未产生明显并发症。在95次检查中,74次没有任何意外情况。最常见的副作用是欣快感。该方法似乎适用于一般临床应用。