Abstract

BACKGROUND

Intussusception is a common, potentially life-threatening paediatric condition. Non-operative treatment with an air enema has been established as the clinical gold standard. There is no validated model for the training of this procedure. Our aim was to produce a novel air enema reduction simulator and validate its use as a training tool.

METHODS

A low-cost paediatric intussusception air enema simulator was created. It was designed to include essential key clinical procedural steps. Participants included both procedural experts and novices from the Departments of Paediatric Radiology and Surgery. The simulator was assessed for face and content validity and its physical, conceptual and experiential fidelity by a structured questionnaire using a 5-point Likert's scale. Statistical analysis included a t-test, and a P-value of <0.05 was considered significant.

RESULTS

Twenty-four clinicians completed the simulation activity (expert: 13 and novices: 11). All experts had performed a minimum of 40 clinical procedures, and 46% had performed >50 procedures. All scores were favourable in all domains for face and content validity: 3.5 (physical appearance), 3.3 (insertion of the tube and taping), 3.1 (holding of the buttocks) and 3.5 (performing the air enema). The simulator also scored highly with fidelity assessment; visual 3.5, conceptual 3.4. There was no difference in procedural confidence with experts (3.8 versus 3.6, P = 0.28), but there was for novices (1.0 versus 2.9, P = 0.0002).

CONCLUSIONS

This low-cost air enema reduction simulator for intussusception has an excellent educational potential for use in a training program in a tertiary centre, as well as, resource-constrained environments.

摘要

背景

肠套叠是一种常见的、可能危及生命的儿科疾病。空气灌肠非手术治疗已成为临床金标准。目前尚无用于该操作培训的经过验证的模型。我们的目标是制作一种新型空气灌肠复位模拟器,并验证其作为培训工具的用途。

方法

制作了一种低成本的儿科肠套叠空气灌肠模拟器。其设计包含了关键的临床操作步骤。参与者包括儿科放射科和外科的操作专家和新手。通过使用5点李克特量表的结构化问卷对模拟器进行了表面效度和内容效度以及其物理、概念和体验逼真度的评估。统计分析包括t检验,P值<0.05被认为具有统计学意义。

结果

24名临床医生完成了模拟活动(专家13名,新手11名)。所有专家至少进行了40次临床操作,46%的专家进行了超过50次操作。在表面效度和内容效度的所有领域,所有评分均良好:3.5(外观)、3.3(插管和固定)、3.1(托住臀部)和3.5(进行空气灌肠)。模拟器在逼真度评估中得分也很高;视觉方面3.5分,概念方面3.4分。专家在操作信心方面没有差异(3.8对3.6,P = 0.28),但新手有差异(1.0对2.9,P = 0.0002)。

结论

这种低成本的肠套叠空气灌肠复位模拟器在三级中心以及资源有限的环境中的培训项目中具有出色的教育潜力。