Suppr超能文献

Ⅱ类复合树脂修复体微渗漏的微计算机断层扫描评估:一项研究。

Micro-computed tomography evaluation of microleakage of Class II composite restorations: An study.

作者信息

Zavattini Angelo, Mancini Manuele, Higginson James, Foschi Federico, Pasquantonio Guido, Mangani Francesco

机构信息

Department of Restorative Dentistry, School of Dentistry, Cardiff University, Cardiff, UK.

Department of Clinical Sciences and Translational Medicine, University of Rome Tor Vergata, Rome RM, Italy.

出版信息

Eur J Dent. 2018 Jul-Sep;12(3):369-374. doi: 10.4103/ejd.ejd_28_18.

Abstract

OBJECTIVE

The aim of this study is to investigate the microleakage attained with three resin-based material used to restore deep Class II cavities. A null hypothesis was chosen: there is no difference in microleakage among the tested materials.

MATERIALS AND METHODS

A total of 30 Class II cavities were prepared in freshly extracted molars with the proximal mesial and distal margins located, respectively, 1.5 mm apically and 1.5 mm coronally to the cementum-enamel junction. Restorations were completed using a three-step enamel-dentin adhesive system "Etch and Rinse," margins were relocated using a micro-hybrid, preheated, or flowable composite and restorations were then completed using a conventional composite. All samples were coated with nail varnish with the exception of an area along the margins and apex was sealed using epoxide cement and then thermocycled (30-s dwell time, 5°C/55°C, 1000 cycles). A 50% ammoniac AgNO3 solution was used as tracer according to Tay's protocol. The microleakage analysis was performed using a microtomography system Sky-scan 1072 (SKYSCAN, Kartuizersweg 3B 2550, Konitch, Belgium).

RESULTS

The mean microleakage of all the tested materials showed greater leakage in the cementum margins; flowable composite exhibit greater leakage among the groups. Significant differences ( < 5%) within groups in both enamel and dentin margins were present. None of the tested materials eliminated marginal microleakage. Preheated composite showed significantly lesser microleakage.

CONCLUSION

Tested materials showed statistical differences in microleakage; thus, the null hypothesis has been rejected. Within the limitations of the present experimental procedure, it can be concluded that flowable resin composite should be avoided at the dentin/cementum margin.

摘要

目的

本研究旨在调查三种用于修复Ⅱ类深龋洞的树脂基材料的微渗漏情况。采用零假设:受试材料之间的微渗漏无差异。

材料与方法

在新鲜拔除的磨牙上制备30个Ⅱ类洞,近中邻面和远中边缘分别位于牙骨质-釉质界根尖方1.5 mm和冠方1.5 mm处。使用三步法釉质-牙本质粘结系统“酸蚀冲洗法”完成修复,边缘用微混合、预热或流动复合树脂重新定位,然后用传统复合树脂完成修复。除边缘区域外,所有样本均涂有指甲油,根尖区域用环氧树脂封闭,然后进行热循环(停留时间30秒,5°C/55°C,1000次循环)。根据Tay的方案,使用50%的硝酸银氨溶液作为示踪剂。使用Sky-scan 1072微型断层扫描系统(SKYSCAN,Kartuizersweg 3B 2550,比利时科尼奇)进行微渗漏分析。

结果

所有受试材料的平均微渗漏在牙骨质边缘显示出更大的渗漏;流动复合树脂在各组中表现出更大的渗漏。在釉质和牙本质边缘组内均存在显著差异(<5%)。没有一种受试材料能消除边缘微渗漏。预热复合树脂显示出明显较少的微渗漏。

结论

受试材料在微渗漏方面存在统计学差异;因此,零假设被拒绝。在本实验程序的限制范围内,可以得出结论,在牙本质/牙骨质边缘应避免使用流动树脂复合材料。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/da0b/6089047/7d21a2386ef6/EJD-12-369-g002.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验