Suppr超能文献

一种新型可穿戴式心电图和呼吸动态 Holter 监测设备的定性和定量评估。

Qualitative and quantitative evaluation of a new wearable device for ECG and respiratory Holter monitoring.

机构信息

Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano, Italy.

Centro Cardiologico Monzino, IRCCS, Milano, Italy; Dept. of Clinical Sciences and Community Health, Cardiovascular Section, University of Milano, Milano, Italy.

出版信息

Int J Cardiol. 2018 Dec 1;272:231-237. doi: 10.1016/j.ijcard.2018.06.044. Epub 2018 Jun 13.

Abstract

BACKGROUND

Recent advances in wearable technology make continuous cardiorespiratory monitoring possible, with potential applications in assessment of cardiopulmonary patients, healthy subjects and athletes. The aim of the present study was to qualitatively and quantitatively evaluate a new wearable device (Learn Inspire Free Entertain = L.I.F.E.) by embedding in a compression shirt a 12‑lead ECG system and 5 respiratory sensors.

METHODS

Thirty cardiorespiratory patients and ten healthy subjects were studied for 24 h during their usual life activities. In 8 healthy subjects, simultaneous measurements of the device and of an ergo-spirometer were performed during different levels of ventilation in five different body positions. The quality of ECG signals in terms of measurability of heart rate, P wave, QRS complex and ST segment, was analyzed by four expert cardiologists/respiratory physiologists using an arbitrary 1-5 scale. The sum of the respiratory signals was used to calculate the respiratory rate, inspiratory time and relative changes of tidal volume. These parameters were compared to ergo-spirometer measurements.

RESULTS

Median quality value was >3 for heart rate, QRS complex, ST segment and P wave (except in L3, aVL, aVF, V1 and V2 leads). Median quality of respiratory traces was >4 in patients and between 3 and 4 in healthy subjects. The respiratory monitoring of respiratory rate and inspiratory time was accurate in all body positions. Tidal volumes were underestimated due to a high level of ventilation.

CONCLUSIONS

The L.I.F.E. device provides an accurate continuous monitoring of cardiorespiratory signals during the 24 h both in normal subjects and cardiorespiratory patients.

摘要

背景

可穿戴技术的最新进展使得连续的心肺监测成为可能,在评估心肺患者、健康受试者和运动员方面具有潜在的应用。本研究的目的是通过在压缩衬衫中嵌入 12 导联心电图系统和 5 个呼吸传感器,对一种新的可穿戴设备(Learn Inspire Free Entertain= L.I.F.E.)进行定性和定量评估。

方法

30 名心肺患者和 10 名健康受试者在日常活动中进行了 24 小时的研究。在 8 名健康受试者中,在不同的通气水平和 5 种不同的体位下,同时对设备和呼吸量计进行了测量。4 位专家心血管医生/呼吸生理学家使用任意 1-5 分制对心电图信号的质量进行了分析,以评估心率、P 波、QRS 复合体和 ST 段的可测量性。使用呼吸信号的总和来计算呼吸频率、吸气时间和潮气量的相对变化。将这些参数与呼吸量计的测量值进行了比较。

结果

中位数质量值>3 的心电率、QRS 复合体、ST 段和 P 波(除了 L3、aVL、aVF、V1 和 V2 导联)。中位数质量>4 的患者和中位数 3-4 的健康受试者的呼吸轨迹。在所有体位下,呼吸率和吸气时间的呼吸监测均准确。由于通气水平较高,潮气量被低估。

结论

L.I.F.E. 设备在正常受试者和心肺患者的 24 小时内都能提供准确的心肺信号连续监测。