Med Biol Eng Comput. 2019 Jan;57(1):1-13. doi: 10.1007/s11517-018-1887-z. Epub 2018 Aug 29.
Osteoporosis is one of the most common diseases that leads to bone fractures. Dual-energy X-ray absorptiometry is currently employed to measure the bone mineral density and to diagnose osteoporosis. Alternatively, the dielectric properties of bones are found to be influenced by bone mineral density; hence, dielectric properties of bones may potentially be used to diagnose osteoporosis. Microwave tomographic imaging is currently in development to potentially measure in vivo dielectric properties of bone. Therefore, the foci of this work are to summarize all available dielectric data of bone in the microwave frequency range and to analyze the confounders that may have resulted in variations in reported data. This study also compares the relationship between the dielectric properties and bone quality reported across different studies. The review suggests that variations exist in the dielectric properties of bone and the relationship between bone volume fraction and dielectric properties is in agreement across all studies. Conversely, the evidence of a relationship between bone mineral density and dielectric properties is inconsistent across the studies. This summary of dielectric data of bone along with a comparison of the relationship between the dielectric properties and bone quality will accelerate the development of microwave tomographic imaging devices for the monitoring of osteoporosis. Graphical abstract ᅟ.
骨质疏松症是导致骨折的最常见疾病之一。目前,双能 X 射线吸收法被用于测量骨矿物质密度和诊断骨质疏松症。此外,骨头的介电特性被发现受骨矿物质密度的影响;因此,骨头的介电特性可能可用于诊断骨质疏松症。微波层析成像目前正在开发中,以潜在地测量骨的体内介电特性。因此,这项工作的重点是总结微波频率范围内所有可用的骨介电数据,并分析可能导致报告数据变化的混杂因素。本研究还比较了不同研究报告的骨介电特性与骨质量之间的关系。综述表明,骨的介电特性存在差异,并且在所有研究中,骨体积分数与介电特性之间的关系是一致的。相反,骨矿物质密度与介电特性之间关系的证据在研究之间不一致。本研究总结了骨的介电数据,并比较了骨介电特性与骨质量之间的关系,这将加速用于监测骨质疏松症的微波层析成像设备的开发。