极性顺序和电极激活顺序对人工耳蜗使用者响度的影响。

The effect of polarity order and electrode-activation order on loudness in cochlear implant users.

机构信息

Department of Otolaryngology, New York University School of Medicine, 550 First Avenue, NBV 5E5, New York, New York 10016, USA

出版信息

J Acoust Soc Am. 2018 Aug;144(2):EL112. doi: 10.1121/1.5049701.

Abstract

This study examined the interaction between polarity and electrode-activation order on loudness in cochlear implant users. Pulses were presented with the polarity of the leading phase alternating or constant across channels. Electrode-activation order was either consecutive or staggered. Staggered electrode-activation orders required less current for equal loudness than consecutive orders with constant polarity. Consecutive electrode-activation orders required less current than staggered orders with alternating polarity. The results support the hypothesis that crosstalk between channels can interfere with or facilitate neuronal activation depending on polarity.

摘要

本研究考察了极性和电极激活顺序对人工耳蜗使用者响度的相互作用。在通道之间交替或恒定的领先相位极性下呈现脉冲。电极激活顺序为连续或交错。交错电极激活顺序所需的电流小于具有恒定极性的连续顺序。具有交替极性的连续电极激活顺序所需的电流小于交错顺序。结果支持这样的假设,即通道之间的串扰可以根据极性干扰或促进神经元激活。

相似文献

2
6
Temporal-gap detection by cochlear prosthesis users.
J Speech Hear Res. 1989 Dec;32(4):849-56. doi: 10.1044/jshr.3204.849.
7
Single- and multi-channel modulation detection in cochlear implant users.人工耳蜗使用者的单通道和多通道调制检测
PLoS One. 2014 Jun 11;9(6):e99338. doi: 10.1371/journal.pone.0099338. eCollection 2014.
10
Effect of Pulse Rate on Loudness Discrimination in Cochlear Implant Users.脉搏率对人工耳蜗使用者响度辨别能力的影响。
J Assoc Res Otolaryngol. 2018 Jun;19(3):287-299. doi: 10.1007/s10162-018-0658-8. Epub 2018 Mar 12.

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验