Healy Aoife, Linyard-Tough Kimberley, Chockalingam Nachiappan
Staffordshire University, School of Life Sciences and Education, Staffordshire University, Stoke On Trent ST4 2DF, UK e-mail: .
J Biomech Eng. 2019 Jan 1;141(1). doi: 10.1115/1.4041619.
While previous research has assessed the validity of the OptoGait system to the GAITRite walkway and an instrumented treadmill, no research to date has assessed this system against a traditional three-dimensional motion analysis system. Additionally, previous research has shown that the OptoGait system shows systematic bias when compared to other systems due to the configuration of the system's hardware. This study examined the agreement between the spatiotemporal gait parameters calculated from the OptoGait system and a three-dimensional motion capture (14 camera Vicon motion capture system and 2 AMTI force plates) in healthy adults. Additionally, a range of filter settings for the OptoGait were examined to determine if it was possible to eliminate any systematic bias between the OptoGait and the three-dimensional motion analysis system. Agreement between the systems was examined using 95% limits of agreement by Bland and Altman and the intraclass correlation coefficient. A repeated measure ANOVA was used to detect any systematic differences between the systems. Findings confirm the validity of the OptoGait system for the evaluation of spatiotemporal gait parameters in healthy adults. Furthermore, recommendations on filter settings which eliminate the systematic bias between the OptoGait and the three-dimensional motion analysis system are provided.
虽然先前的研究已经评估了OptoGait系统相对于GAITRite步道和仪器化跑步机的有效性,但迄今为止,尚无研究将该系统与传统的三维运动分析系统进行对比评估。此外,先前的研究表明,由于系统硬件配置的原因,OptoGait系统与其他系统相比存在系统偏差。本研究考察了健康成年人中,OptoGait系统计算得出的时空步态参数与三维运动捕捉(14台摄像机的Vicon运动捕捉系统和2块AMTI测力板)之间的一致性。此外,还研究了一系列OptoGait的滤波设置,以确定是否有可能消除OptoGait与三维运动分析系统之间的任何系统偏差。使用Bland和Altman的95%一致性界限以及组内相关系数来检验系统之间的一致性。采用重复测量方差分析来检测系统之间的任何系统差异。研究结果证实了OptoGait系统在评估健康成年人时空步态参数方面的有效性。此外,还提供了关于滤波设置的建议,这些设置可消除OptoGait与三维运动分析系统之间的系统偏差。