Abstract

Early screening of gastric cancer is a critical importance for the improvement of patients' survival rate. Here, a polyethylene coating Lamb (PE-Lamb) microfluidic device with immune layer for gastric cancer label-free detection was constructed. Two serum pepsinogen 1 (PG1) and pepsinogen 2 (PG2) biomarkers were applied to screen and predict the appearance of gastric cancer. Compared with enzyme-linked immunosorbent assay (ELISA), this method achieved a higher sensitivity and less time (40 min vs 120 min). The limit of detections (LOD) were reached 60 pg/mL for PG1 and 30 pg/mL for PG2, which have two orders of magnitude lower than traditional ELISA. The linearity coefficient indexes (R) for PG1 and PG2 were 0.992 and 0.953 respectively, which is similar to that of ELISA. In addition, PG1 and PG2 mixed antigens sample with human serum was detected by PE-Lamb approach, and the frequency response showed high reproducibility and specificity. The results indicate that PE-lamb diagnostic technique is a novel and promising method for high-throughput screening and early diagnosis of gastric cancer.

摘要

早期胃癌筛查对提高患者生存率至关重要。本文构建了一种具有免疫层的聚乙烯涂层羔羊(PE-Lamb)微流控装置,用于无标记胃癌检测。两种血清胃蛋白酶原 1(PG1)和胃蛋白酶原 2(PG2)生物标志物被用于筛选和预测胃癌的发生。与酶联免疫吸附测定(ELISA)相比,该方法具有更高的灵敏度和更短的检测时间(40min 对 120min)。PG1 和 PG2 的检测限(LOD)分别达到 60pg/mL 和 30pg/mL,比传统 ELISA 低两个数量级。PG1 和 PG2 的线性系数指标(R)分别为 0.992 和 0.953,与 ELISA 相似。此外,PE-Lamb 方法还检测了含有混合人血清的 PG1 和 PG2 混合抗原样品,其频率响应显示出良好的重现性和特异性。结果表明,PE-lamb 诊断技术是一种用于高通量筛选和早期诊断胃癌的新颖而有前途的方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验