Pansheriya Ekta, Goel Manish, Gupta Kapil Dev, Ahuja Ravish, Kaur Rupinder Deep, Garg Vishal
Department of Pedodontics and Preventive Dentistry and Daswani Dental College and Research Centre, Kota, Rajasthan, India.
Department of Pedodontics and Preventive Dentistry, Maulana Azad Institute of Dental Sciences, New Delhi, India.
Contemp Clin Dent. 2018 Sep;9(Suppl 2):S215-S220. doi: 10.4103/ccd.ccd_17_18.
Objective in root canal preparation is to develop a shape that tapers from apical to coronal, maintaining the original canal shape. With advent of instruments manufactured from nickel-titanium (NiTi) alloys, there was a significant improvement of quality of root canal shaping, with predictable results and less iatrogenic damage.
The aim of the study was to evaluate the canal centric ability and apical transportation in apical region of newer NiTi file system in root canal using cone-beam computed tomography (CBCT) on extracted molars.
Root canal of thirty extracted human permanent teeth with mature root apices with 20°-40° of curvature were collected and divided into three groups after initial bio-mechanical preparation: Group 1: canal prepared using ProTaperNext (PTN) file system; Group 2: canal prepared using Mani silk system; and Group 3: canal prepared using V-taper file system. All samples were scanned before and after biomechanical preparation using CBCT. The data collected were evaluated using the Kruskal-Wallis analysis of variance test and Mann-Whitney U-test.
It was observed that in apical region Group I (PTN) showed significantly lower mean apical transportation and canal centric ability as compared to Group II (Mani Silk) and Group III (V-taper).
It was concluded that PTN rotary system has no canal transportation and maintained centric ability in comparison to Mani and V-taper rotary file system in apical region of curved root canal.
根管预备的目标是形成一种从根尖向冠方逐渐变细的形态,同时保持原始根管形态。随着镍钛(NiTi)合金制造的器械的出现,根管塑形质量有了显著提高,结果可预测且医源性损伤更少。
本研究的目的是使用锥形束计算机断层扫描(CBCT)对拔除的磨牙进行根管内新型NiTi锉系统根尖区的根管中心定位能力和根尖移位评估。
收集30颗根尖成熟、弯曲度为20°-40°的拔除人类恒牙的根管,在初始生物力学预备后分为三组:第1组:使用ProTaperNext(PTN)锉系统预备根管;第2组:使用Mani丝系统预备根管;第3组:使用V型锉系统预备根管。所有样本在生物力学预备前后均使用CBCT进行扫描。收集的数据使用Kruskal-Wallis方差分析检验和Mann-Whitney U检验进行评估。
观察到在根尖区,与第2组(Mani丝)和第3组(V型锉)相比,第1组(PTN)的平均根尖移位和根管中心定位能力显著更低。