Suppr超能文献

镀银不锈钢丝与未镀银不锈钢丝摩擦阻力的比较评估:一项研究。

Comparative Evaluation of Frictional Resistance of Silver-Coated Stainless Steel Wires with Uncoated Stainless Steel Wires: An Study.

作者信息

Shah Priyanka K, Sharma Padmaja, Goje Santosh Kumar

机构信息

Department of Orthodontics and Dentofacial Orthopedics, K. M. Shah Dental College and Hospital, Sumandeep Vidyapeeeth, Vadodara, Gujarat, India.

出版信息

Contemp Clin Dent. 2018 Sep;9(Suppl 2):S331-S336. doi: 10.4103/ccd.ccd_405_18.

Abstract

BACKGROUND

Silver is known for its antimicrobial activity. Silver coating effectively reduces and count, thus reducing chances of dental plaque and caries. This silver coating may have effect on frictional property of orthodontic wires.

AIM

The aim of this study is to evaluate and compare frictional resistance of silver-coated and uncoated stainless steel (SS) wires.

METHODS

Forty SS wires were divided into four groups of 10 each: Group 1 - 0.017 × 0.025 inch SS wires (silver coated), Group 2 - 0.017 × 0.025 inch SS wires (control), Group 3 - 0.019 × 0.025 inch SS wires (silver coated), and Group 4 - 0.019 × 0.025 inch SS wires (control). Surface modification of wires was carried out by the thermal vacuum evaporation method with silver (10 nm size) using vacuum-coating unit model. The frictional resistances of all forty wires were checked on forty 0.022 × 0.028 inch slot central incisor brackets (SS wires and brackets from American Orthodontics, St Paul, USA) mounted on metal plates using universal testing machine.

RESULTS

There was no significant difference found in frictional resistance between silver-coated and uncoated 0.017 × 0.025 inch SS wires group ( = 0.854). Statistically significant reduction in frictional resistance was observed in 0.019 × 0.025 inch coated SS wires in comparison to uncoated wires ( = 0.032).

CONCLUSION

Overall silver coating either did not affect the frictional resistance (0.017 × 0.025 inch SS wires) or reduced it (0.019 × 0.025 inch coated SS wires) compared to uncoated wires. Findings suggest that the use of silver-coated SS wires in routine orthodontic practice can be implemented after further human clinical trials.

摘要

背景

银以其抗菌活性而闻名。银涂层能有效减少细菌数量,从而降低牙菌斑和龋齿的发生几率。这种银涂层可能会对正畸钢丝的摩擦性能产生影响。

目的

本研究旨在评估和比较涂银和未涂银的不锈钢(SS)钢丝的摩擦阻力。

方法

将40根SS钢丝分为四组,每组10根:第1组 - 0.017×0.025英寸的SS钢丝(涂银),第2组 - 0.017×0.025英寸的SS钢丝(对照组),第3组 - 0.019×0.025英寸的SS钢丝(涂银),第4组 - 0.019×0.025英寸的SS钢丝(对照组)。使用真空镀膜单元模型通过热真空蒸发法用银(尺寸为10纳米)对钢丝进行表面改性。使用万能试验机在安装在金属板上的40个0.022×0.028英寸槽中央门牙托槽(美国正畸公司,圣保罗,美国的SS钢丝和托槽)上检查所有40根钢丝的摩擦阻力。

结果

涂银和未涂银的0.017×0.025英寸SS钢丝组之间的摩擦阻力没有显著差异(P = 0.854)。与未涂银的钢丝相比,0.019×0.025英寸涂银的SS钢丝的摩擦阻力在统计学上有显著降低(P = 0.032)。

结论

总体而言,与未涂银的钢丝相比,银涂层要么不影响摩擦阻力(0.017×0.025英寸的SS钢丝),要么降低了摩擦阻力(0.019×0.025英寸涂银的SS钢丝)。研究结果表明,经过进一步的人体临床试验后,可以在常规正畸实践中使用涂银的SS钢丝。