文献检索文档翻译深度研究
Suppr Zotero 插件Zotero 插件
邀请有礼套餐&价格历史记录

新学期,新优惠

限时优惠:9月1日-9月22日

30天高级会员仅需29元

1天体验卡首发特惠仅需5.99元

了解详情
不再提醒
插件&应用
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
高级版
套餐订阅购买积分包
AI 工具
文献检索文档翻译深度研究
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2025

生物电阻抗设备与双能 X 射线吸收法和人体测量法评估成人身体成分的比较。

Comparison of a Bioelectrical Impedance Device against the Reference Method Dual Energy X-Ray Absorptiometry and Anthropometry for the Evaluation of Body Composition in Adults.

机构信息

Department of Nutrition, Dietetics and Food, Monash University, Notting Hill, VIC 3168, Australia.

School of Psychological Sciences, Monash University, Clayton, VIC 3168, Australia.

出版信息

Nutrients. 2018 Oct 10;10(10):1469. doi: 10.3390/nu10101469.


DOI:10.3390/nu10101469
PMID:30308974
原文链接:https://pmc.ncbi.nlm.nih.gov/articles/PMC6213252/
Abstract

This study aimed to compare the use of the bioelectrical impedance device (BIA) seca mBCA 515 using dual X-ray absorptiometry (DXA) as a reference method, for body composition assessment in adults across the spectrum of body mass indices. It explores the utility of simple anthropometric measures (the waist height ratio (WHtR) and waist circumference (WC)) for the assessment of obesity. In the morning after an overnight fast (10 h), 30 participants underwent a body composition DXA (GE iDXA) scan, BIA (seca 515), and anthropometric measures. Compared to the DXA reference measure, the BIA underestimated fat mass (FM) by 0.32 kg (limits of agreement -3.8 kg, 4.4 kg); overestimated fat free mass (FFM) by 0.43 kg (limits of agreement -8.2 kg, 4.3 kg). Some of the variation was explained by body mass index (BMI), as for FM, the mean difference of the normal range BMI group was smaller than for the overweight/obese group (0.25 kg and 0.35 kg, respectively) with wider limits of agreement (-4.30 kg, 4.81 kg, and -3.61 kg, 4.30 kg, respectively). There were significant differences in visceral adipose tissue (VAT) volume measurements between methods with BIA systematically overestimating VAT compared to DXA. WC was more strongly correlated with DXA FM (rho = 0.90, < 0.001) than WHtR (rho = 0.83, < 0.001). BIA had some agreement with DXA; however, they are not equivalent measures for the range of BMIs explored, with DXA remaining the more informative tool. WC is a useful and simple assessment tool for obesity.

摘要

本研究旨在比较生物电阻抗设备(BIA)seca mBCA 515 与双能 X 射线吸收法(DXA)作为参考方法在不同体质量指数范围内评估成人身体成分的应用。它探讨了简单人体测量学指标(腰高比(WHtR)和腰围(WC))在肥胖评估中的效用。在禁食 10 小时后的早晨,30 名参与者接受了身体成分 DXA(GE iDXA)扫描、BIA(seca 515)和人体测量学测量。与 DXA 参考测量相比,BIA 低估了脂肪量(FM)0.32kg(一致性范围-3.8kg,4.4kg);高估了去脂体重(FFM)0.43kg(一致性范围-8.2kg,4.3kg)。部分变异可以用体重指数(BMI)来解释,因为对于 FM,正常范围 BMI 组的平均差值小于超重/肥胖组(分别为 0.25kg 和 0.35kg),一致性范围更宽(分别为-4.30kg,4.81kg,和-3.61kg,4.30kg)。两种方法测量内脏脂肪组织(VAT)体积存在显著差异,BIA 系统高估了 VAT。WC 与 DXA FM 的相关性更强(rho=0.90,<0.001),而 WHtR 与 DXA FM 的相关性较弱(rho=0.83,<0.001)。BIA 与 DXA 有一定的一致性;然而,它们不是所探索 BMI 范围内的等效测量方法,DXA 仍然是更具信息量的工具。WC 是一种有用且简单的肥胖评估工具。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f832/6213252/f162b2e1ce3f/nutrients-10-01469-g002.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f832/6213252/03c59c88d295/nutrients-10-01469-g001.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f832/6213252/f162b2e1ce3f/nutrients-10-01469-g002.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f832/6213252/03c59c88d295/nutrients-10-01469-g001.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f832/6213252/f162b2e1ce3f/nutrients-10-01469-g002.jpg

相似文献

[1]
Comparison of a Bioelectrical Impedance Device against the Reference Method Dual Energy X-Ray Absorptiometry and Anthropometry for the Evaluation of Body Composition in Adults.

Nutrients. 2018-10-10

[2]
Comparison of body composition methods in overweight and obese Brazilian women.

Arq Bras Endocrinol Metabol. 2010-6

[3]
Assessing body composition among 3- to 8-year-old children: anthropometry, BIA, and DXA.

Obes Res. 2004-10

[4]
Comparison of body composition measures assessed by bioelectrical impedance analysis versus dual-energy X-ray absorptiometry in the United Kingdom Biobank.

Clin Nutr ESPEN. 2024-10

[5]
Validity of segmental multiple-frequency bioelectrical impedance analysis to estimate body composition of adults across a range of body mass indexes.

Nutrition. 2009-1

[6]
Agreement of bioelectrical impedance with dual-energy X-ray absorptiometry and MRI to estimate changes in body fat, skeletal muscle and visceral fat during a 12-month weight loss intervention.

Br J Nutr. 2012-8-31

[7]
Relationship between indices of obesity obtained by anthropometry and dual-energy X-ray absorptiometry: The Fourth and Fifth Korea National Health and Nutrition Examination Survey (KNHANES IV and V, 2008-2011).

Obes Res Clin Pract. 2015

[8]
[Comparative analysis of body composition assessment methods in healthy men and in chronic obstructive pulmonary disease patients: anthropometry, bioelectrical impedance and dual-energy X-ray absorptiometry].

Arch Latinoam Nutr. 2005-6

[9]
Fat-free mass prediction equations for bioelectric impedance analysis compared to dual energy X-ray absorptiometry in obese adolescents: a validation study.

BMC Pediatr. 2015-10-15

[10]
Validation of multi-frequency bioelectrical impedance analysis versus dual-energy X-ray absorptiometry to measure body fat percentage in overweight/obese Colombian adults.

Am J Hum Biol. 2017-10-7

引用本文的文献

[1]
The relationship between cardiorespiratory fitness and indices of fat mass and fat-free mass in adults.

Front Sports Act Living. 2025-7-24

[2]
Association Between Bioimpedance-Determined Metabolic Age and MASLD Risk Scores in Spanish Workers.

Metabolites. 2025-5-21

[3]
Relationship Between Metabolic Age Determined by Bioimpedance and Insulin Resistance Risk Scales in Spanish Workers.

Nutrients. 2025-3-8

[4]
Relative validity of bioelectrical impedance analysis in estimating body composition in women with overweight and obesity 2 weeks and 6 months postpartum.

Food Nutr Res. 2025-1-24

[5]
Validity between dual-energy x-ray absorptiometry and bioelectrical impedance for segmental fat analysis and a novel low-cost model developed using anthropometry in young adults.

J Transl Med. 2025-1-10

[6]
Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components.

Front Nutr. 2024-12-3

[7]
Body composition analysis using bioelectric impedance in Bissau: reproducibility and level of agreement between two available devices.

Pan Afr Med J. 2024

[8]
Adiposity modifies the association between heart failure risk and glucose metabolic disorder in older individuals: a community-based prospective cohort study.

Cardiovasc Diabetol. 2024-8-27

[9]
BODYFAT: a new calculator to determine the risk of being overweight validated in Spanish children between 11 and 17 years of age.

Eur J Pediatr. 2024-9

[10]
Associations between 47 anthropometric markers derived from a body scanner and relative fat-free mass in a population-based study.

BMC Public Health. 2024-4-18

本文引用的文献

[1]
Longitudinal validity of abdominal adiposity assessment by regional bioelectrical impedance.

Eur J Clin Nutr. 2018-3-20

[2]
Metabolic Dysfunction, Obesity, and Survival Among Patients With Early-Stage Colorectal Cancer.

J Clin Oncol. 2016-10-20

[3]
Comparison of visceral fat mass measurement by dual-X-ray absorptiometry and magnetic resonance imaging in a multiethnic cohort: the Dallas Heart Study.

Nutr Diabetes. 2016-7-18

[4]
Bioelectrical impedance is an accurate method to assess body composition in obese but not severely obese adolescents.

Nutr Res. 2016-7

[5]
Body Fat Distribution and Risk of Incident and Regressed Nonalcoholic Fatty Liver Disease.

Clin Gastroenterol Hepatol. 2015-7-27

[6]
Abdominal adiposity distribution in diabetic/prediabetic and nondiabetic populations: a meta-analysis.

J Obes. 2014

[7]
Global estimates of diabetes prevalence for 2013 and projections for 2035.

Diabetes Res Clin Pract. 2013-12-1

[8]
Validation of anthropometric indices of adiposity against whole-body magnetic resonance imaging--a study within the German European Prospective Investigation into Cancer and Nutrition (EPIC) cohorts.

PLoS One. 2014-3-13

[9]
Validation study of multi-frequency bioelectrical impedance with dual-energy X-ray absorptiometry among obese patients.

Obes Surg. 2014-9

[10]
Overview of epidemiology and contribution of obesity to cardiovascular disease.

Prog Cardiovasc Dis. 2013-10-24

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索