Kim Seok Hwan, Shin Ho Seong
Department of Plastic and Reconstructive Surgery, College of Medicine, Soonchunhyang University, Bucheon, Korea.
J Craniofac Surg. 2018 Nov;29(8):2048-2054. doi: 10.1097/SCS.0000000000004781.
The prime aims of this study were to establish cephalometric linear and angular normative values of the lower face using a three-dimensional (3D) analysis in Korean individuals, and validate whether the linear and angular measurements using 3D laser scanner are comparable with measurements using 3D computed tomography (CT).
In this study, 40 Korean individuals aged between 18 and 60 years were enrolled. Using 3D CT scan and 3D laser scanner, linear and angular values of the lower face were measured and recorded. Statistical analysis was carried out to verify the concordance and correlation between two 3D imaging modalities.
The 40 samples consisted of 11 women with a mean age of 40.8 ± 14.5 years and 29 men with a mean age of 29.7 ± 15.0 years. The results demonstrated the difference between sex and the tendency of asymmetry on both sides. Among different methods of measuring angular values, the gonial angle (GA) between tragion' (Tr')-gonion' (Go')-menton' (Me') from 3D laser scanning and between articulate-gonion-menton from CT scan demonstrated a good concordance and a high correlation.
The GA measured between Tr'-Go'-Me' using a 3D facial laser scan was comparable with values from 3D CT scan. The reference points and the GA, which we assessed here for 3D laser scanning, can be a reliable alternative method evaluating mandibular angles for assessing patients and surgical planning in plastic and orthognathic surgery.
本研究的主要目的是利用三维(3D)分析确定韩国人群下面部的头影测量线性和角度正常值,并验证使用3D激光扫描仪进行的线性和角度测量是否与使用3D计算机断层扫描(CT)的测量结果具有可比性。
本研究纳入了40名年龄在18至60岁之间的韩国人。使用3D CT扫描和3D激光扫描仪测量并记录下面部的线性和角度值。进行统计分析以验证两种3D成像方式之间的一致性和相关性。
40个样本包括11名女性,平均年龄为40.8±14.5岁,以及29名男性,平均年龄为29.7±15.0岁。结果显示了性别差异以及两侧不对称的趋势。在测量角度值的不同方法中,3D激光扫描得出的耳点(Tr')-下颌角点(Go')-颏下点(Me')之间的下颌角(GA)与CT扫描得出的关节点-下颌角点-颏下点之间的下颌角显示出良好的一致性和高度相关性。
使用3D面部激光扫描测量的Tr'-Go'-Me'之间的GA与3D CT扫描的值具有可比性。我们在此评估的3D激光扫描的参考点和GA可以作为一种可靠的替代方法,用于在整形外科和正颌外科手术中评估患者和进行手术规划时评估下颌角。