Ziola B R, Matikainen M T, Salmi A
J Immunol Methods. 1977;17(3-4):309-17. doi: 10.1016/0022-1759(77)90113-2.
Polystyrene balls have been incorporated as the solid-phase of a model double-antibody radioimmunoassay for human serum albumin. Purified IgG from the secondary antiserum is adsorbed on the 6.4 mm diameter balls. The solid-phase secondary antibody is then used to separate primary antibody bound iodinated antigen from unbound antigen. The secondary antibody coated polystyrene balls are easily prepared and manipulated; several hundred sample dilutions can readily be processed in a single assay. Assay background values of 1.5% or less are consistently obtained without extensive or special washing procedures.
聚苯乙烯球已被用作人血清白蛋白模型双抗体放射免疫测定的固相。来自第二抗血清的纯化IgG吸附在直径6.4毫米的球上。然后用固相二抗将结合了碘化抗原的一抗与未结合的抗原分离。包被二抗的聚苯乙烯球易于制备和操作;一次测定中可以轻松处理数百个样品稀释液。无需广泛或特殊的洗涤程序,即可始终获得1.5%或更低的测定背景值。