Sonoda Shozo, Terasaki Hiroto, Kakiuchi Naoko, Shiihara Hideki, Sakoguchi Tomonori, Tomita Masatoshi, Shinohara Yuki, Yamashita Takehiro, Uchino Eisuke, Sakamoto Taiji
Department of Ophthalmology, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan.
Jpn J Ophthalmol. 2019 Jan;63(1):82-89. doi: 10.1007/s10384-018-0631-4. Epub 2018 Oct 24.
To determine the capabilities of the "Kago-Eye2" software to semi-automatically segment the choroid in the optical coherence tomographic (OCT) images.
A cross-sectional, prospective study of 44 healthy volunteers.
The Kago-eye2 software was developed to detect the border between Choriocapillaris and Sattler's layer (C-S) and between Sattler's layer and Haller's layer (S-H). The intra- and inter-grader agreements were determined for the segmentations made with semi-automated and manual analysis using the Kago-Eye2 software. The inter-method agreements were determined for two independent graders.
Forty-four right eyes of 44 heathy volunteers (22 men) with a mean age of 35.0 ± 8.8 years were studied. The intra-grader agreement of the C-S border was 0.97 for grader 1 and 0.892 for grader 2 for the manual segmentation, and 0.908 for grader 1 and 0.842 for grader 2 for the Kago-Eye2 segmentation. For the S-H border, the intra-grader agreement was 0.96 for grader 1 and 0.981 for grader 2 for manual segmentation and 0.855 for grader 1 and 0.839 for grader 2 with the Kago-Eye2. For the C-S and S-H border, the inter-grader agreement was 0.548 and 0.902 for manual segmentation and 0.947 and 0.833 for the Kago-Eye2. The inter-method agreement was 0.565 for the C-S border and 0.759 for the S-H border.
The Kago-Eye2 software can segment the layers of the subfoveal choroid with good reproducibility and repeatability. We conclude that the Kago-Eye2 software can be used for semi-automatic segmentation of the choroidal layers.
确定“Kago-Eye2”软件在光学相干断层扫描(OCT)图像中半自动分割脉络膜的能力。
对44名健康志愿者进行的横断面前瞻性研究。
开发Kago-eye2软件以检测脉络膜毛细血管层与萨特勒层(C-S)之间以及萨特勒层与哈勒层(S-H)之间的边界。使用Kago-Eye2软件对半自动和手动分析所做的分割确定分级者内和分级者间的一致性。对两名独立分级者确定方法间的一致性。
研究了44名健康志愿者(22名男性)的44只右眼,平均年龄为35.0±8.8岁。对于手动分割,分级者1对C-S边界的分级者内一致性为0.97,分级者2为0.892;对于Kago-Eye2分割,分级者1为0.908,分级者2为0.842。对于S-H边界,手动分割分级者1的分级者内一致性为0.96,分级者2为0.981;使用Kago-Eye2时,分级者1为0.855,分级者2为0.839。对于C-S和S-H边界,手动分割的分级者间一致性为0.548和0.902,Kago-Eye2为0.947和0.833。方法间一致性对于C-S边界为0.565,对于S-H边界为0.759。
Kago-Eye2软件能够以良好的重现性和可重复性分割黄斑下脉络膜各层。我们得出结论,Kago-Eye2软件可用于脉络膜层的半自动分割。