Talanta. 2019 Feb 1;193:139-145. doi: 10.1016/j.talanta.2018.09.089. Epub 2018 Sep 25.
A comparison of the performance of two electrochemical immunosensors for the determination of the anorexigen biomarker peptide YY (PYY) is reported by using as scaffolds screen printed gold electrodes modified either by oxidative grafting of p-aminobenzoic acid (p-ABA) or by assembling of a 4-mercaptobenzoic acid (4-MBA) SAM. Covalent immobilization of capture antibodies on the surface-confined carboxyl groups was carried out by EDC/NHSS chemistry, and competitive immunoassays between target PYY and Biotin-PYY were implemented. Upon labeling with alkaline phosphatase (AP)-streptavidin conjugate and 1-naphtyl phosphate addition, differential pulse voltammograms recorded between -0.2 and +0.7 V were used as analytical readout. All the steps involved in the functionalization of the electrodes and the preparation of the immunosensors were monitored by electrochemical impedance spectroscopy. The calibration plot for PYY using the AP-Strept-Biotin-PYY(PYY)-anti-PYY-Phe-N-SPAuE immunosensor provided a linear current vs. log [PYY] plot extending between 10 and 10 ng/mL PYY with a detection limit of 3 × 10 ng/mL. These analytical characteristics are remarkably better than those obtained with the immunosensor prepared with 4-MBA SAM-SPAuEs. The AP-Strept-Biotin-PYY(PYY)-anti-PYY-Phe-N-SPAuE immunosensor was used to analyze human serum and saliva samples spiked with PYY at concentrations fitting with normal levels in these biological fluids.
本文报道了两种电化学免疫传感器用于测定厌食标志物肽 YY(PYY)的性能比较,这两种传感器的支架分别是通过氧化接枝对氨基苯甲酸(p-ABA)或组装 4-巯基苯甲酸(4-MBA)自组装单分子层修饰的丝网印刷金电极。通过 EDC/NHSS 化学将捕获抗体共价固定在表面受限的羧基上,并进行了目标 PYY 与生物素化 PYY 之间的竞争性免疫分析。在碱性磷酸酶(AP)-链霉亲和素缀合物标记和添加 1-萘基磷酸后,记录的在-0.2 至+0.7 V 之间的差分脉冲伏安图用作分析读数。通过电化学阻抗谱监测了电极功能化和免疫传感器制备过程中的所有步骤。使用 AP-Strept-Biotin-PYY(PYY)-抗 PYY-Phe-N-SPAuE 免疫传感器对 PYY 进行校准,得到的线性电流与 log [PYY] 图在 10 至 10 ng/mL PYY 之间延伸,检测限为 3×10 ng/mL。这些分析特性明显优于使用 4-MBA SAM-SPAuEs 制备的免疫传感器获得的特性。AP-Strept-Biotin-PYY(PYY)-抗 PYY-Phe-N-SPAuE 免疫传感器用于分析人血清和唾液样本,这些样本中 PYY 的浓度与这些生物流体中的正常水平相匹配。