Suppr超能文献

种植体表面会影响骨结合过程中的种植体稳定性吗?一项随机临床试验。

Can implant surfaces affect implant stability during osseointegration? A randomized clinical trial.

作者信息

Carmo Filho Luiz Carlos do, Marcello-Machado Raissa Micaella, Castilhos Eduardo Dickie de, Del Bel Cury Altair Antoninha, Faot Fernanda

机构信息

Universidade Estadual de Campinas - Unicamp, Piracicaba Dental School, Department of Prosthodontics and Periodontology, Piracicaba, SP, Brazil.

Universidade Federal de Pelotas - UFPel, School of Dentistry, Department of Social and Preventive Dentistry, elotas, RS, Brazil.

出版信息

Braz Oral Res. 2018 Oct 25;32:e110. doi: 10.1590/1807-3107bor-2018.vol32.0110.

Abstract

This randomized clinical trial evaluated the insertion torque (IT), primary, and secondary stability of dental implants with different surface treatments during the osseointegration period. Nineteen patients with bilateral partial edentulism in the posterior mandibular region were randomly allocated to two implant brand groups and received implants with different surface treatments in the opposite site of the arch: Osseotite and Nanotite or SLA and SLActive. During implant placement, the maximum IT was recorded using a surgical motor equipped with a graphical user interface. The implant stability quotient (ISQ) was assessed immediately after the IT, and was measured weekly via resonance frequency analysis during 3 months. The data were analyzed by a one-way ANOVA, the Bonferroni test, paired t tests and Pearson's correlation coefficient. The IT values were similar (p > 0.05) for all implant types ranging from 43.82 ± 6.50 to 46.84 ± 5.06. All implant types behaved similarly until the 28th day (p > 0.05). Between 35 and 56 days, Osseotite and SLActive showed lower ISQ values (p < 0.001) compared to Nanotite and SLA implants. After 56 days, only Osseotite maintained significantly lower ISQ values than the other implants (p < 0.05). After 91 days the ISQ values were significantly higher than the baseline for all four implant types (p < 0.001). The ISQ and IT values were significantly correlated at the baseline and at the final evaluation for Osseotite, Nanotite, and SLActive implants (p < 0.001). After 91 days, ISQ and IT values were only significantly correlated for the Osseotite implants (p < 0.05). All implants types exhibited acceptable primary and secondary stability.

摘要

这项随机临床试验评估了在骨整合期不同表面处理的牙种植体的植入扭矩(IT)、初期稳定性和二期稳定性。19例下颌后牙区双侧部分牙列缺损患者被随机分为两个种植体品牌组,在牙弓的对侧部位接受不同表面处理的种植体:骨钛(Osseotite)和纳米钛(Nanotite)或喷砂酸蚀大颗粒(SLA)和活性喷砂酸蚀(SLActive)。在种植体植入过程中,使用配备图形用户界面的手术电机记录最大IT。在记录IT后立即评估种植体稳定性商数(ISQ),并在3个月内每周通过共振频率分析进行测量。数据采用单因素方差分析、Bonferroni检验、配对t检验和Pearson相关系数进行分析。所有种植体类型的IT值相似(p>0.05),范围为43.82±6.50至46.84±5.06。所有种植体类型在第28天前表现相似(p>0.05)。在35至56天之间,与纳米钛和SLA种植体相比,骨钛和SLActive种植体的ISQ值较低(p<0.001)。56天后,只有骨钛种植体的ISQ值显著低于其他种植体(p<0.05)。91天后,所有四种种植体类型的ISQ值均显著高于基线(p<0.001)。对于骨钛、纳米钛和SLActive种植体,在基线和最终评估时,ISQ和IT值显著相关(p<0.001)。91天后,仅骨钛种植体的ISQ和IT值显著相关(p<0.05)。所有种植体类型均表现出可接受的初期和二期稳定性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验