Johnson Carl A, Melvin Amber L, Robinson Davida A, Amirjamshidi Hossein, Knight Peter A, Gosev Igor
From the Division of Cardiac Surgery, University of Rochester Medical Center, Rochester, NY USA.
Innovations (Phila). 2018 Sep/Oct;13(5):361-364. doi: 10.1097/IMI.0000000000000560.
The objective of this study was to investigate the feasibility of using titanium fasteners for securement of the inflow sewing ring during HeartMate 3 implantation. The secondary objective was to compare cardiopulmonary bypass and total operative times between the titanium fastener and hand-tied knot groups.
Clearance between the sewing ring and the HeartMate 3 device was assessed in vitro. Thirty-one patients undergoing HeartMate 3 implantation via median sternotomy at a single center from April 2017 to February 2018 were reviewed. The sewing ring was secured with hand-tied knots (n = 18) or titanium fasteners (n = 13). Cannulation strategy and implantation technique were otherwise identical between groups. Central arterial and venous cannulation was performed for cardiopulmonary bypass. The left ventricular apex was cored, and the sewing ring was attached with hand-tied knots or titanium fasteners.
There was adequate clearance for the titanium fastener to secure the inflow sewing ring and then connect to the HeartMate 3 in vitro. The inflow sewing ring was successfully secured during HeartMate 3 implantation in the titanium fastener group. Cardiopulmonary bypass time was 75 and 92 minutes for the titanium fastener and hand-tied groups, respectively (P < 0.03). Total operative time was 177 and 193 minutes for the titanium fastener and hand-tied groups, respectively (P = 0.513).
The inflow sewing ring of the HeartMate 3 was efficiently secured using titanium fasteners. Titanium fasteners resulted in shorter cardiopulmonary bypass times compared with the hand-tied group. There was no difference in total operative time.
本研究的目的是探讨在植入HeartMate 3期间使用钛制紧固件固定流入缝合环的可行性。次要目的是比较钛制紧固件组和手工打结组之间的体外循环时间和总手术时间。
在体外评估缝合环与HeartMate 3装置之间的间隙。回顾了2017年4月至2018年2月在单一中心通过正中胸骨切开术植入HeartMate 3的31例患者。缝合环采用手工打结固定(n = 18)或钛制紧固件固定(n = 13)。两组的插管策略和植入技术在其他方面相同。进行体外循环时采用中心动脉和静脉插管。在左心室心尖打孔,然后用手工打结或钛制紧固件连接缝合环。
在体外,钛制紧固件有足够的间隙来固定流入缝合环,然后连接到HeartMate 3。在钛制紧固件组的HeartMate 3植入过程中,流入缝合环成功固定。钛制紧固件组和手工打结组的体外循环时间分别为75分钟和92分钟(P < 0.03)。钛制紧固件组和手工打结组的总手术时间分别为177分钟和193分钟(P = 0.513)。
使用钛制紧固件可有效固定HeartMate 3的流入缝合环。与手工打结组相比,钛制紧固件可缩短体外循环时间。总手术时间无差异。