视网膜前膜患者的视网膜图像质量和对比敏感度函数:一项横断面观察性临床研究。

Retinal-image quality and contrast sensitivity function in eyes with epiretinal membrane: a cross-sectional observational clinical study.

作者信息

Liu Limei, Wang Yi, Liu Ju, Liu Wu

机构信息

Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijng Ophthalmology and Visual Sciences Key Laboratory, Beijing, China.

Department of Ophthalmology, Yantai Yuhuangding Hospital, Affiliated Hospital of Medical College, Qingdao University, Yantai, Shandong, China.

出版信息

BMC Ophthalmol. 2018 Nov 7;18(1):290. doi: 10.1186/s12886-018-0957-1.

Abstract

BACKGROUND

To investigate the effect of idiopathic epiretinal membrane (ERM) on the retinal-image quality and psychophysical contrast sensitivity function (CSF).

METHODS

Forty-four subjects with diagnosis of idiopathic unilateral ERM were enrolled in this cross-sectional observational clinical study. The fellow unaffected eyes were set as the control group. For retinal-image quality assessment, an Optical Quality Analysis System (OQAS) based on double-pass technique was used to evaluate objective scatter index (OSI) and Strehl ratio. For visual performance, the CSF under photopic condition was measured.

RESULTS

For retinal-image quality, the result of double-pass device revealed a significant lower Strehl ratio and larger OSI in the ERM eyes compared to the fellow eyes (all P < 0.05). For visual performance, the CSF at all spatial frequencies under photopic condition were also significantly degraded in the ERM eyes compared to the fellow eyes (all P < 0.05). For the ERM eyes, the reduction of Strehl ratio and CSF was 29.41 and 54.39%, respectively, and the increase of OSI was 164.10% compared to the fellow eyes. Besides, BCVA significantly correlated to the total CSF (ERM eyes, r = - 0.53, P < 0.001; the fellow eyes, r = - 0.467, P = 0.002) and Strehl ratio (ERM eyes, r = - 0.485, P = 0.001; the fellow eyes, r = - 0.311, P = 0.043) in both of the ERM and the fellow eyes.

CONCLUSION

Eyes affected with ERM showed poorer retinal-image quality and visual performance than the normal eyes. Retinal-image quality measured by OQAS based on double-pass technique could be useful for assessing the retinal-image quality for ERM-affected eyes, in which retinal scattering was significantly increased.

摘要

背景

探讨特发性视网膜前膜(ERM)对视网膜图像质量及心理物理学对比敏感度函数(CSF)的影响。

方法

44例诊断为特发性单侧ERM的受试者纳入本横断面观察性临床研究。将对侧未受影响的眼设为对照组。对于视网膜图像质量评估,使用基于双程技术的光学质量分析系统(OQAS)评估客观散射指数(OSI)和斯特列尔比。对于视觉功能,测量明视条件下的CSF。

结果

对于视网膜图像质量,双程设备的结果显示,与对侧眼相比,ERM眼的斯特列尔比显著降低,OSI增大(均P<0.05)。对于视觉功能,与对侧眼相比,ERM眼在明视条件下所有空间频率的CSF也显著下降(均P<0.05)。与对侧眼相比,ERM眼的斯特列尔比降低了29.41%,CSF降低了54.39%,OSI增加了164.10%。此外,在ERM眼和对侧眼中,最佳矫正视力(BCVA)与总CSF(ERM眼,r=-0.53,P<0.001;对侧眼,r=-0.467, P=0.002)和斯特列尔比(ERM眼,r=-0.485,P=0.001;对侧眼,r=-0.,311,P=0.043)均显著相关。

结论

与正常眼相比,患有ERM的眼睛视网膜图像质量和视觉功能较差。基于双程技术的OQAS测量的视网膜图像质量可用于评估受ERM影响的眼睛的视网膜图像质量,其中视网膜散射显著增加。