Shafijan Shaik Mohammad, Chandrasekaran Ashok, Balakrishnan Umamaheswari, Ninan Binu, Abiramalatha Thangaraj
Department of Neonatology, Sri Ramachandra Medical College and Research Institute, Porur, Chennai, Tamil Nadu, India.
Indian Pediatr. 2018 Oct 15;55(10):914-915.
We aimed to compare continuous temperature-monitoring using Bluetooth-enabled thermometer (BET) and intermittent monitoring by digital thermometer (DT) in neonates. Continuous monitoring using BET identified 377 episodes of hypo/hyperthermias in 90 baby-days; 316 (83.8%) episodes were confirmed by DT and 61 (16.2%) were false alarms. Five episodes were missed by BET. The agreement between digital thermometer and BET was good. Continuous temperature monitoring helps in early identification of hypo/hyperthermia in neonates.
我们旨在比较使用蓝牙温度计(BET)对新生儿进行连续体温监测与使用数字温度计(DT)进行间歇监测的效果。使用BET进行连续监测在90个婴儿日中识别出377次体温过低/过高事件;其中316次(83.8%)事件经DT确认,61次(16.2%)为误报。BET漏报了5次事件。数字温度计与BET之间的一致性良好。连续体温监测有助于早期识别新生儿的体温过低/过高情况。