Hossain A, Ramia S, Bakir T M
Department of Pathology, Faculty of Medicine, King Saud University, Riyadh, Saudi Arabia.
J Trop Med Hyg. 1988 Aug;91(4):216-21.
Comparative evaluations of immune status for rubella are described for the enzyme-linked immunosorbent assay (ELISA), indirect immunofluorescence (IFA) and two standard haemagglutination inhibition tests (HAI kaolin; HAI heparin-MnCl2). In general, a reasonably good correlation was obtained between the level of rubella antibodies measured by the HAI (kaolin) test and by ELISA, but an appreciable proportion (15%) of ELISA positive specimens were encountered among HAI (kaolin) negative sera. All of these HAI negative, ELISA positive sera, except one were found to be positive for rubella antibodies by IFA. Neutralization test performed on this serum positive by ELISA only, confirmed the presence of protective rubella antibodies. Of all the tests evaluated ELISA appeared unequivocally to be the most sensitive test followed closely by IFA. The standard HAI (heparin-MnCl2) was more suitable than the HAI (kaolin), for the determination of immune status. Further, no linear relationship between single rubella virus HAI and ELISA values was observed.
本文描述了酶联免疫吸附测定(ELISA)、间接免疫荧光法(IFA)以及两种标准血凝抑制试验(高岭土血凝抑制试验;肝素 - 氯化锰血凝抑制试验)对风疹免疫状态的比较评估。总体而言,通过高岭土血凝抑制试验和ELISA检测的风疹抗体水平之间获得了较好的相关性,但在高岭土血凝抑制试验阴性血清中发现了相当比例(15%)的ELISA阳性标本。所有这些高岭土血凝抑制试验阴性、ELISA阳性的血清,除一份外,经IFA检测风疹抗体均为阳性。仅对这份ELISA阳性血清进行中和试验,证实存在保护性风疹抗体。在所有评估的试验中,ELISA显然是最敏感的试验,其次是IFA。标准肝素 - 氯化锰血凝抑制试验比高岭土血凝抑制试验更适合用于确定免疫状态。此外,未观察到单一风疹病毒血凝抑制试验值与ELISA值之间的线性关系。