犬尿中γ-谷氨酰转移酶(GGT)分光光度测定法的验证及41只健康犬尿GGT与肌酐比值参考区间和生物学变异的测定

Validation of a spectrophotometric method for GGT measurement in canine urine and determination of the urine GGT-to-creatinine ratio reference interval and biological variation in 41 healthy dogs.

作者信息

Ilchyshyn Nicholas P, Villiers Elizabeth, Monti Paola

机构信息

Dick White Diagnostics, Dick White Referrals, Six Mile Bottom, Cambridgeshire, UK.

出版信息

J Vet Diagn Invest. 2019 Jan;31(1):33-39. doi: 10.1177/1040638718812927. Epub 2018 Nov 18.

Abstract

The urine gamma-glutamyl transferase (GGT)-to-creatinine ratio has been used to monitor patients at risk of acute renal injury. We validated the spectrophotometric quantification of GGT in urine in a commercial biochemistry analyzer. The assay was precise, accurate, and linear. Intra-assay precision was 3.59% in 4 samples, with GGT concentrations of 47-195 U/L. Inter-assay precision in 3 samples with activities of 11-51 U/L was 7.74%. Accuracy was 97.3%, with an absolute bias of 2.7 U/L. Urine GGT was unaffected by hematuria, hemoglobinuria, or bacteriuria. Urine GGT was stable at 20°C and 4°C for up to 3 d. Storage by freezing at -20°C resulted in a significant reduction in enzyme activity. A pH outside the range of 6.5-8 resulted in reduced GGT activity. The biological variation of urine GGT-to-creatinine ratio provided an index of individuality of 1.6, indicating that a population-based reference interval (RI) can be used. The reference change value was calculated, and an increase in consecutive measurements >43% is required to be regarded as significant. The urine GGT-to-creatinine ratio RI obtained in a population of 41 healthy dogs was 8.5-28.5 U/g.

摘要

尿γ-谷氨酰转移酶(GGT)与肌酐比值已被用于监测有急性肾损伤风险的患者。我们在商用生化分析仪中验证了尿中GGT的分光光度法定量。该检测方法精确、准确且呈线性。在GGT浓度为47 - 195 U/L的4个样本中,批内精密度为3.59%。在活性为11 - 51 U/L的3个样本中,批间精密度为7.74%。准确度为97.3%,绝对偏差为2.7 U/L。尿GGT不受血尿、血红蛋白尿或菌尿的影响。尿GGT在20°C和4°C下可稳定保存3天。在 - 20°C冷冻保存会导致酶活性显著降低。pH值在6.5 - 8范围之外会导致GGT活性降低。尿GGT与肌酐比值的生物学变异提供了一个个体性指数为1.6,表明可以使用基于群体的参考区间(RI)。计算了参考变化值,连续测量值增加>43%才被视为有显著意义。在41只健康犬的群体中获得的尿GGT与肌酐比值RI为8.5 - 28.5 U/g。

相似文献

8
False positivity of gamma-glutamyl transpeptidase measurement in urine.尿γ-谷氨酰转肽酶检测的假阳性。
Ren Fail. 2014 May;36(4):581-4. doi: 10.3109/0886022X.2014.880325. Epub 2014 Jan 23.

本文引用的文献

2
Renal biomarkers in domestic species.家畜中的肾脏生物标志物。
Vet Clin Pathol. 2016 Mar;45(1):28-56. doi: 10.1111/vcp.12333. Epub 2016 Feb 26.
8
Urinary enzyme evaluation of nephrotoxicity in the dog.犬肾毒性的尿酶评估
Toxicol Pathol. 1998 Jan-Feb;26(1):29-32. doi: 10.1177/019262339802600104.
10
Circadian variation of urinary enzymes in the dog.犬尿酶的昼夜变化
J Vet Med Sci. 1994 Oct;56(5):849-54. doi: 10.1292/jvms.56.849.