QuantiFERON Gold Plus (Plus) assay has two approved methods for blood collection: direct in-tube (Plus direct) or the transfer of blood from a lithium heparin tube (Plus transfer). Currently, there is little data comparing the results of Plus and the QuantiFERON Gold In-Tube (Gold) based on blood collection.
In 2017, high risk healthcare workers undergoing annual tuberculosis infection screening at Houston Methodist Hospital, a private hospital in the Texas Medical Center (Houston, TX, U.S.A.) were consented and enrolled in a study comparing the Gold-in-tube (Gold), Plus direct in-tube, and Plus transfer assays. Blood was drawn concurrently for all 3 assays.
Phlebotomy occurred on 300 consecutive, consented and enrolled participants in the study. The proportion of positive test results for the Gold, Plus direct and Plus transfer assays were 10% (29/300), 12% (35/299) and 17% (51/299), respectively. The agreement in the results of Gold versus Plus direct, Gold versus Plus transfer, and Plus direct versus Plus transfer was 91%, kappa (κ) = 0.56; 91%, κ = 0.59; and 85%, κ = 0.37, respectively.
Among high risk healthcare workers in a low prevalence tuberculosis setting, the Gold Plus assay had a higher proportion of positive results than the Gold in-tube assay. The agreement between the Gold, Plus direct and Plus transfer assays was unexpectedly low for simultaneously obtained samples. Blood transfer using lithium heparin offers individual clinics and public health programs greater ability to customize protocols, but variability of results still exists.
QuantiFERON Gold Plus(Plus)检测法有两种经批准的采血方法:直接管内(Plus direct)或从肝素锂管转移血液(Plus transfer)。目前,基于采血方法比较 Plus 和 QuantiFERON Gold In-Tube(Gold)检测结果的数据很少。
2017 年,在美国德克萨斯医学中心(休斯顿,TX,美国)的休斯顿卫理公会医院接受年度结核病感染筛查的高风险医护人员在同意并参与了一项比较 Gold-in-tube(Gold)、Plus direct in-tube 和 Plus transfer 检测的研究。所有 3 种检测均同时采血。
该研究连续纳入了 300 名连续同意并参与的参与者,Gold、Plus direct 和 Plus transfer 检测的阳性检测结果比例分别为 10%(29/300)、12%(35/299)和 17%(51/299)。Gold 与 Plus direct、Gold 与 Plus transfer、Plus direct 与 Plus transfer 的结果一致性分别为 91%,κ(κ)=0.56;91%,κ=0.59;85%,κ=0.37。
在低流行结核病环境中,高风险医护人员中 Gold Plus 检测法的阳性结果比例高于 Gold in-tube 检测法。同时获得的样本中,Gold、Plus direct 和 Plus transfer 检测之间的一致性出乎意料地低。使用肝素锂的血液转移为个别诊所和公共卫生计划提供了更大的协议定制能力,但结果仍存在差异。